Detailed Information

Cited 42 time in webofscience Cited 47 time in scopus
Metadata Downloads

Polypyrrole-MXene supported gold nanoparticles for the trace-level detection of nitrofurantoinopen access

Authors
Vilian, A.T. EzhilHwang, Seung-KyuBhaskaran, GokulAlhammadi, MunirahKim, SuheonTiwari, Jitendra N.Huh, Yun SukHan, Young-Kyu
Issue Date
Feb-2023
Publisher
Elsevier B.V.
Keywords
MXene; Polypyrrole; Gold nanoparticles; Amperometry; Nitrofurantoin; Electrochemical analysis
Citation
Chemical Engineering Journal, v.454, pp 1 - 11
Pages
11
Indexed
SCIE
SCOPUS
Journal Title
Chemical Engineering Journal
Volume
454
Start Page
1
End Page
11
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/25827
DOI
10.1016/j.cej.2022.139980
ISSN
1385-8947
1873-3212
Abstract
High usage of nitrofurantoin (NFT) has resulted in unacceptable levels in water and foods with negative impacts on animals, humans, and surrounding ecosystems. The accurate and ultra-low sensing of NFT in waterways presents a significant societal challenge. To address this issue, gold nanoparticles (AuNPs) were integrated into polypyrrole (PPy) on Titanium carbide MXene (Ti3C2Tx) using a simple sonochemical route involving the in-situ, oxidant-free polymerization of pyrrole monomer in the presence of HAuCl4. The AuNP-PPy-MXene composite produced was used to modify a glassy carbon electrode (GCE) to construct an ultrasensitive electrochemical sensor for the direct and on-site sensing of NFT in complex samples. Electrochemical impedance spectroscopy (EIS) investigations showed Au-PPy-MXene-GCEs had a heterogeneous electron transfer rate constant (k degrees) of 1.03 x 10(-2) cm s(-1) and a lower charge-transfer resistance (R-ct = 73 Omega) than Au-MXene, Au-PPy, and PPy-MXene GCEs. In addition, Au-PPy-MXene-GCE exhibited better electrocatalytic reduction performance at a higher cathodic signal intensity and a lower reduction overpotential of -0.38 V (vs Ag/AgCl) for NFT than Au-MXene, Au-PPy, and PPy-MXene GCEs. The fabricated sensor had a wide linear range from 6 to 172 nM (measured at -0.38 V vs Ag/AgCl), an ultra-low detection limit (LOD) of 0.26 nM (at S/N = 3), and an excellent sensitivity of 6.4121 mu A nM(-1) cm(-2) for the electroreduction of NFT. Au-PPy-MXene-GCE also provided specific and accurate amperometric analysis for NFT in the presence of cationic, anionic, and other potentially interfering pesticides. The practicality of the sensor was tested to quantify NFT at trace levels in complex matrices (honey, pond water, and hospital wastewater samples), and achieved recoveries ranging between 97.6 % and 113.2 % and a relative standard deviation of<3.6 %.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Energy and Materials Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Vilian, Ayyar Thevar Ezhil photo

Vilian, Ayyar Thevar Ezhil
College of Engineering (Department of Energy and Materials Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE