Cited 47 time in
Polypyrrole-MXene supported gold nanoparticles for the trace-level detection of nitrofurantoin
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Vilian, A.T. Ezhil | - |
| dc.contributor.author | Hwang, Seung-Kyu | - |
| dc.contributor.author | Bhaskaran, Gokul | - |
| dc.contributor.author | Alhammadi, Munirah | - |
| dc.contributor.author | Kim, Suheon | - |
| dc.contributor.author | Tiwari, Jitendra N. | - |
| dc.contributor.author | Huh, Yun Suk | - |
| dc.contributor.author | Han, Young-Kyu | - |
| dc.date.accessioned | 2024-09-26T17:00:48Z | - |
| dc.date.available | 2024-09-26T17:00:48Z | - |
| dc.date.issued | 2023-02 | - |
| dc.identifier.issn | 1385-8947 | - |
| dc.identifier.issn | 1873-3212 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/25827 | - |
| dc.description.abstract | High usage of nitrofurantoin (NFT) has resulted in unacceptable levels in water and foods with negative impacts on animals, humans, and surrounding ecosystems. The accurate and ultra-low sensing of NFT in waterways presents a significant societal challenge. To address this issue, gold nanoparticles (AuNPs) were integrated into polypyrrole (PPy) on Titanium carbide MXene (Ti3C2Tx) using a simple sonochemical route involving the in-situ, oxidant-free polymerization of pyrrole monomer in the presence of HAuCl4. The AuNP-PPy-MXene composite produced was used to modify a glassy carbon electrode (GCE) to construct an ultrasensitive electrochemical sensor for the direct and on-site sensing of NFT in complex samples. Electrochemical impedance spectroscopy (EIS) investigations showed Au-PPy-MXene-GCEs had a heterogeneous electron transfer rate constant (k degrees) of 1.03 x 10(-2) cm s(-1) and a lower charge-transfer resistance (R-ct = 73 Omega) than Au-MXene, Au-PPy, and PPy-MXene GCEs. In addition, Au-PPy-MXene-GCE exhibited better electrocatalytic reduction performance at a higher cathodic signal intensity and a lower reduction overpotential of -0.38 V (vs Ag/AgCl) for NFT than Au-MXene, Au-PPy, and PPy-MXene GCEs. The fabricated sensor had a wide linear range from 6 to 172 nM (measured at -0.38 V vs Ag/AgCl), an ultra-low detection limit (LOD) of 0.26 nM (at S/N = 3), and an excellent sensitivity of 6.4121 mu A nM(-1) cm(-2) for the electroreduction of NFT. Au-PPy-MXene-GCE also provided specific and accurate amperometric analysis for NFT in the presence of cationic, anionic, and other potentially interfering pesticides. The practicality of the sensor was tested to quantify NFT at trace levels in complex matrices (honey, pond water, and hospital wastewater samples), and achieved recoveries ranging between 97.6 % and 113.2 % and a relative standard deviation of<3.6 %. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier B.V. | - |
| dc.title | Polypyrrole-MXene supported gold nanoparticles for the trace-level detection of nitrofurantoin | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.cej.2022.139980 | - |
| dc.identifier.scopusid | 2-s2.0-85142424105 | - |
| dc.identifier.wosid | 000910332500001 | - |
| dc.identifier.bibliographicCitation | Chemical Engineering Journal, v.454, pp 1 - 11 | - |
| dc.citation.title | Chemical Engineering Journal | - |
| dc.citation.volume | 454 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 11 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Chemical | - |
| dc.subject.keywordPlus | PERFORMANCE LIQUID-CHROMATOGRAPHY | - |
| dc.subject.keywordPlus | ELECTROCHEMICAL SENSORS | - |
| dc.subject.keywordAuthor | MXene | - |
| dc.subject.keywordAuthor | Polypyrrole | - |
| dc.subject.keywordAuthor | Gold nanoparticles | - |
| dc.subject.keywordAuthor | Amperometry | - |
| dc.subject.keywordAuthor | Nitrofurantoin | - |
| dc.subject.keywordAuthor | Electrochemical analysis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.