Micro-hole array fluorescent sensor based on AC-Dielectrophoresis (DEP) for simultaneous analysis of nano-molecules

Authors
Kim, Hye JinKang, Dong-HoonLee, EunjiHwang, Kyo SeonShin, Hyun-JoonKim, JinsikPark, Jung Ho
Issue Date
2018
Publisher
SPIE-INT SOC OPTICAL ENGINEERING
Keywords
Dielectrophoresis; simultaneous analysis; nano-molecules; micro-hole array
Citation
ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XVI, v.10484
Indexed
SCOPUS
Journal Title
ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XVI
Volume
10484
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/9994
DOI
10.1117/12.2291359
ISSN
0277-786X
1996-756X
Abstract
We propose a simple fluorescent bio-chip based on two types of alternative current-dielectrophoretic (AC-DEP) force, attractive (positive DEP) and repulsive (negative DEP) force, for simultaneous nano-molecules analysis. Various radius of micro-holes on the bio-chip are designed to apply the different AC-DEP forces, and the nano-molecules are concentrated inside the micro-hole arrays according to the intensity of the DEP force. The bio-chip was fabricated by Micro Electro Mechanical system (MEMS) technique, and was composed of two layers; a SiO2 layer and Ta/Pt layer were accomplished for an insulation layer and a top electrode with micro-hole arrays to apply electric fields for DEP force, respectively. Each SiO2 and Ta/Pt layers were deposited by thermal oxidation and sputtering, and micro-hole arrays were fabricated with Inductively Coupled Plasma (ICP) etching process. For generation of each positive and negative DEP at micro-holes, we applied two types of sine-wave AC voltage with different frequency range alternately. The intensity of the DEP force was controlled by the radius of the micro-hole and size of nano-molecule, and calculated with COMSOL multi-physics. Three types of nano-molecules labelled with different fluorescent dye were used and the intensity of nano-molecules was examined by the fluorescent optical analysis after applying the DEP force. By analyzing the fluorescent intensities of the nano-molecules, we verify the various nano-molecules in analyte are located successfully inside corresponding micro-holes with different radius according to their size.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jin Sik photo

Kim, Jin Sik
College of Life Science and Biotechnology (Department of Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE