Detailed Information

Cited 96 time in webofscience Cited 133 time in scopus
Metadata Downloads

A smart nanosensor for the detection of human immunodeficiency virus and associated cardiovascular and arthritis diseases using functionalized graphene-based transistors

Authors
Islam, SauravShukla, ShrutiBajpai, Vivek K.Han, Young-KyuHuh, Yun SukKumar, AshokGhosh, ArindamGandhi, Sonu
Issue Date
1-Feb-2019
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Biosensor; Graphene; Immunoassay; Transistor; HIV; Cardiac troponin 1; Rheumatoid arthritis
Citation
BIOSENSORS & BIOELECTRONICS, v.126, pp 792 - 799
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
126
Start Page
792
End Page
799
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/8407
DOI
10.1016/j.bios.2018.11.041
ISSN
0956-5663
1873-4235
Abstract
Human immunodeficiency virus (HIV), which isa worldwide public health issue, is commonly associated with cardiovascular disorders (CVDs) and rheumatoid arthritis (RA). A smart nanosensor was developed for the detection of HIV and its related diseases (CVDs and RA) using graphene-based field-effect transistors (FETs). In this study, amine-functionalized graphene (afG) was conjugated with antibodies [anti-p24 for HIV, anti-cardiac troponin 1 (anti-cTn1) for CVDs, and anti-cyclic citrullinated peptide (anti-CCP) for RA] to detect various biomarkers. The antibodies were covalently conjugated to afG via carbodiimide activation. The bioconjugate (graphene-antibody) was characterized by various biophysical techniques such as UV-Vis, Raman spectroscopy, scanning electron microscopy (SEM), and atomic force microscopy (AFM). The electrochemical performance of the sensor was evaluated with respect to changes in the resistance of the electrode surface due to the interaction of the antigen with its specific antibody. The developed sensor was highly sensitive and showed a linear response to p24, cTn1, and, CCP from 1 fg/mL to 1 mu g/mL. The limit of detection (LOD) was 100 fg/mL for p24 and 10 fg/mL for cTn1 and CCP under standard optimized conditions. The graphene-based smart nanodevice demonstrated excellent performance; thus, it could be used for the on-site detection of HIV, CVD, and RA biomarkers in real samples.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Energy and Materials Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Young Kyu photo

Han, Young Kyu
College of Engineering (Department of Energy and Materials Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE