Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Transfer learning-informed sensor validation for detecting and diagnosing unseen air quality faults in underground building environmentopen access

Authors
Ali, UsamaTariq, ShahzebKim, KeugtaeChang-Silva, RobertoYoo, ChangKyoo
Issue Date
Mar-2026
Publisher
Elsevier Ltd
Keywords
Fault detection and diagnosis; Gated residual network; Health risk monitoring; Transfer learning; Ventilation system
Citation
Tunnelling and Underground Space Technology, v.169, pp 1 - 19
Pages
19
Indexed
SCIE
SCOPUS
Journal Title
Tunnelling and Underground Space Technology
Volume
169
Start Page
1
End Page
19
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/62219
DOI
10.1016/j.tust.2025.107299
ISSN
0886-7798
1878-4364
Abstract
In modern underground building environments, data-driven integrated systems are necessary for accurate early warning and health risk assessment. However, sensor validation frameworks in both existing and newly deployed monitoring networks often face challenges due to data insufficiency and unseen fault scenarios, leading to increased energy consumption resulting from inaccurate ventilation control. To address these issues, this study proposes a sensor validation framework that integrates a gated residual network (GRN) with an autoencoder and network adapted transfer learning (TL) to ensure reliable performance under faulty conditions. Fault detection, diagnosis, and identification were initially performed on the source station using the squared prediction error and sensor validity index. Subsequently, a TL-based scheme was applied to adapt the model to the target station, mitigating the impact of data scarcity and unseen fault types on validation accuracy. Finally, the influence of faulty sensor measurements and AE-based TL-GRN reconstructions on ventilation control performance was assessed. The proposed TL-GRN achieved a 94.79% fault detection rate for unseen scenarios, significantly outperforming the GRN-AE (78.65%). Moreover, the proposed framework reduces overall resource usage and lowers carbon emissions by decreasing energy consumption by 13.8% and 19.9% compared to GRN-AE and the faulty condition, respectively. Overall, the proposed framework makes a significant contribution to the development of resilient and self-regulating ventilation systems for next-generation smart and sustainable buildings. © 2025 Elsevier Ltd
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biological and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Keug Tae photo

Kim, Keug Tae
College of Life Science and Biotechnology (Department of Convergent Environmental Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE