Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Smartphone-Assisted Wireless Ultrasensitive Nitrite Detection in Food Samples via Hierarchical MXene/NiCoMn-LDH/Sulfide Heterostructure on Flexible Laser-Induced Graphene Electrodeopen access

Authors
Ranjith, Kugalur ShanmugamMohammadi, AliVilian, A. T. EzhilPark, YonghyeonRaju, Ganji Seeta RamaHuh, Yun SukHan, Young-Kyu
Issue Date
Dec-2025
Publisher
Wiley-VCH GmbH
Keywords
electrochemical detection; flexible electrode; food safety; MXene; nitrite sensor
Citation
Small, v.21, no.51
Indexed
SCIE
SCOPUS
Journal Title
Small
Volume
21
Number
51
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/62181
DOI
10.1002/smll.202510411
ISSN
1613-6810
1613-6829
Abstract
Designing a smartphone in-built, wireless, ultrasensitive hybrid heterostructure-based sensor is challenging, but it is potentially crucial for achieving efficient electrochemical responses related to real-time food safety monitoring. Herein, the pioneering design of a few-layered MXene-tagged NiCoMn-layered double hydroxide (LDH)/amorphous sulfide (MXe/NiCoMn-LDH/S) hollow spheres were fabricated and tagged onto a laser-induced graphene (LIG) electrode for smartphone-based electrochemical detection of nitrite (NO2 -). Benefiting from the unique structural and compositional advantages of MXe/NiCoMn-LDH/S integrated on a flexible LIG electrode platform, the sensor achieved a linear detection range from 0.90 to 25 mu M, and a low detection limit of 0.21 mu M, along with a high sensitivity of 11.88 mu A mu M-1 cm-2. Additionally, using the LSV, the sensor demonstrated a wider linear range from 10 to 860 mu M with a detection limit of 7.38 mu M and sensitivity of 1.15 mu A mu M-1 cm-2. It also demonstrated strong anti-interference capability against various organic and inorganic substances, along with excellent reproducibility, repeatability, and reusability, as well as outstanding stability over 30 days. The proposed point-of-care electrochemical system, featuring a portable and affordable LIG electrode design, along with compact smartphone integrity, highlights its advantages over traditional benchtop potentiostats in real-time water quality monitoring in rural and low-resource areas.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Energy and Materials Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ranjith, Kugalur Shanmugam photo

Ranjith, Kugalur Shanmugam
College of Engineering (Department of Energy and Materials Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE