Deep learning model using cross-sequence learning to identify orbital fractures in radiographs of patients under 20 Yearsopen access
- Authors
- Kim, Joohui; Lee, Seungeun; Ahn, So Min; Choi, Gayoung; Je, Bo-Kyung; Park, Beom Jin; Cho, Yongwon; Oh, Saelin
- Issue Date
- Sep-2025
- Publisher
- FRONTIERS MEDIA SA
- Keywords
- orbital fractures; artificial intelligence; deep learning; radiography; pediatrics
- Citation
- Frontiers in Bioengineering and Biotechnology, v.13
- Indexed
- SCIE
SCOPUS
- Journal Title
- Frontiers in Bioengineering and Biotechnology
- Volume
- 13
- URI
- https://scholarworks.dongguk.edu/handle/sw.dongguk/61580
- DOI
- 10.3389/fbioe.2025.1613417
- ISSN
- 2296-4185
2296-4185
- Abstract
- Orbit fractures under 20 years are a medical emergency requiring urgent surgery with the gold standard modality being high-resolution CT. If radiography could be used to identify patients without fractures, the number of unnecessary CT scans could be reduced. The purpose of this study was to develop and validate a deep learning-based multi-input model with a novel cross-sequence learning method, which outperforms the conventional single-input models, to detect orbital fractures on radiographs of young patients. Development datasets for this retrospective study were acquired from two hospitals (n = 904 and n = 910). The datasets included patients with facial trauma who underwent orbital rim view and CT. The development dataset was split into training, tuning, and internal test sets in 7:1:2 ratios. A radiology resident, pediatric radiologist, and ophthalmic surgeon participated in a two-session observer study examining an internal test set, with or without model assistance. The area under the receiver operating characteristic curve (AUROC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and 95% confidence intervals (CIs) were obtained. Our proposed model detected orbital fractures with an AUROC of 0.802. The sensitivity, specificity, PPV, and NPV of the model achieved 65.8, 86.5, 70.9, and 83.5%, respectively. With model assistance, all values for orbital fracture detection improved for the ophthalmic surgeon, with a statistically significant difference in specificity (P < 0.001). For the radiology resident, specificity exhibited significant improvement with model assistance (P < 0.001). Our proposed model was able to identify orbital fractures on radiographs, reducing unnecessary CT scans and radiation exposure.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - Graduate School > Department of Medicine > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.