Smartwatch-Derived VO2max Prediction Model for Korean Adults: Utilizing Heart Rate and GPS Data from the 12-Minute Cooper Testopen access
- Authors
- Lee, Kihyuk; Kim, Dohee; Shin, Sungeun; Choi, Hongjun; Jang, Ahyun; Chung, Jinwook
- Issue Date
- Mar-2025
- Publisher
- MDPI
- Keywords
- VO2max; prediction model; Cooper test; smartwatch; running
- Citation
- Healthcare, v.13, no.7, pp 1 - 10
- Pages
- 10
- Indexed
- SCIE
SSCI
SCOPUS
- Journal Title
- Healthcare
- Volume
- 13
- Number
- 7
- Start Page
- 1
- End Page
- 10
- URI
- https://scholarworks.dongguk.edu/handle/sw.dongguk/58250
- DOI
- 10.3390/healthcare13070722
- ISSN
- 2227-9032
2227-9032
- Abstract
- Background/Objectives: Recent technological advancements enable smartwatches to measure running distance and heart rate using wearable sensors. This study aimed to analyze the validity of the 12 min Cooper test using a smartwatch and to develop an accurate VO2max prediction model for Korean adults. Methods: A total of 104 adults (53 males: age 35.00 +/- 6.1 years, BMI 24.71 +/- 3.13; 51 females: age 34.82 +/- 6.07 years, BMI 22.24 +/- 2.66) participated. VO2max was measured using a maximal graded treadmill test. Participants performed the Cooper test while wearing a smartwatch, which collected average heart rate, peak heart rate, and running distance. Sex, height, and weight were also included as predictor variables. Multiple regression analysis was conducted to develop a VO2max prediction equation. Model accuracy was assessed using R2 and the standard error of the estimate (SEE). Results: The developed VO2max prediction equation was VO2max = 27.620 + 6.358 (sex; male = 1, female = 0) - 0.012 (height) - 0.202 (weight) - 0.036 (mean HR) + 0.039 (peak HR) + 0.012 (distance) (R2 = 0.853, SEE = 3.176 mL/kg/min, p < 0.001). The intra-class correlation coefficient (ICC) between measured and predicted VO2max using the smartwatch was 0.961, compared to 0.925 for traditional methods. The explanatory power was 86.0% (SEE = 3.024 mL/kg/min) versus 81.0% (SEE = 3.516 mL/kg/min). Conclusions: The smartwatch-based VO2max prediction model demonstrated higher accuracy than traditional methods. This equation is recommended for more precise VO2max estimation in Korean adults.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of the Arts > Department of Sports Culture > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.