Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Nanofiber-shaped Co3O4@In2O3 composite for high-performance enzymeless glucose sensing

Authors
Xu, XindaZhang, ChaoYang, WoochulLi, YujiaLi, BingHaldorai, YuvarajZhenyu, JiangXie, Wanfeng
Issue Date
Mar-2025
Publisher
Royal Society of Chemistry
Keywords
Cobalt; Glucose; Indium; Oxide; Cobalt; Cobalt Oxide; Glucose; Indium; Indium Oxide; Oxides; Electrochemical Sensors; Glucose Sensors; Indium Compounds; Nanoclay; Redox Reactions; Conductivity Limit; Electrical Conductivity; Electrochemicals; Enzymeless; Enzymeless Detections; Enzymeless Glucose Sensing; Glucose Detection; Indium Oxide; Lower Limits Of Detections; Performance; Nanofibers; Cobalt; Cobalt Oxide; Glucose; Indium; Indium Oxide; Nanofiber; Oxide; Chemistry; Electrochemical Analysis; Electrode; Genetic Procedures; Limit Of Detection; Procedures; Biosensing Techniques; Cobalt; Electrochemical Techniques; Electrodes; Glucose; Indium; Limit Of Detection; Oxides
Citation
Nanoscale, v.17, no.11, pp 6718 - 6726
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
Nanoscale
Volume
17
Number
11
Start Page
6718
End Page
6726
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/58028
DOI
10.1039/d4nr04274c
ISSN
2040-3364
2040-3372
Abstract
Cobalt tetraoxide (Co3O4) holds great potential for enzymeless glucose detection due to its strong redox capabilities. However, its poor electrical conductivity limits the charge transfer and hence weakens its catalytic activity when utilized as an electrode in electrochemical sensors, such as an enzymeless glucose sensor. In this study, we developed an indium oxide (In2O3)-wrapped Co3O4 nanofibers (Co3O4@In2O3 NFs)-based electrochemical sensor for the enzymeless detection of glucose, with an ultra-low limit of detection (LoD) of 8.85 nM (S/N = 3), a wide detection range from 10 nM to 118 mu M, and a high sensitivity of 1197.5 mu A mM-1 cm-2. In addition, this sensor exhibits good selectivity, reproducibility, and long-term stability for over 30 days. The sensing performance of bare Co3O4 NFs towards glucose has been significantly enhanced by incorporating them within highly conductive In2O3, which is mainly attributed to the synergistic combination of the electrocatalytic activity of Co3O4 NFs, as the delicately designed core, and the excellent conductivity of In2O3, as the shell. Thus, this novel modified Co3O4@In2O3 NFs electrochemical composite has huge potential to be further developed for enzymeless glucose analysis in practical clinical settings.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Woo Chul photo

Yang, Woo Chul
College of Natural Science (Department of Physics)
Read more

Altmetrics

Total Views & Downloads

BROWSE