Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Surface engineered gold nanodendrites decorated flexible carbon fiber-based electrochemical sensor platform for sensitive detection of L-Cysteine in serum and urine samples

Authors
Arivazhagan, ManiElancheziyan, MariWon, KeehoonJakmunee, Jaroon
Issue Date
May-2025
Publisher
ELSEVIER
Keywords
Flexible carbon fiber; Electrochemical deposition; Electrochemical sensor; L-Cysteine; Au nanodendrites; Biomedical application
Citation
Talanta, v.287, pp 1 - 10
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
Talanta
Volume
287
Start Page
1
End Page
10
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/57864
DOI
10.1016/j.talanta.2025.127688
ISSN
0039-9140
1873-3573
Abstract
In this work, highly dispersed gold nanodendrites (Au NDs) decorated flexible carbon fiber electrode (Au NDs@FCF electrode) were fabricated by facile, green, and one-step electrochemical deposition protocol and utilized for the direct electrochemical determination of L-Cysteine (L-Cys). The prepared Au NDs@FCF electrodes were characterized by SEM, HR-TEM, XRD, XPS, CV, and EIS towards the dimensions, surface morphological traits, crystalline nature, chemical composition, and electrochemical catalytic oxidation towards L-Cys and electrochemical active surface area (ECASA) of the Au NDs. The developed Au NDs@FCF electrode demonstrates an enzyme mimics electrocatalytic efficiency towards the oxidation of L-Cys at the operating potential of 0.82 V (vs Ag/AgCl) with a lower experimental detection limit of 0.16 nM, higher sensitivity of similar to 50.2 mu A mu M-1 cm(-2), and a wide concentration ranges from 100 to 3000 nM with a correlation coefficient of R-2 = 0.996. In addition, the developed Au NDs@FCF electrode has exhibited excellent selectivity with various anti-interferences such as glucose, dopamine, uric acid, Na+, Mg2+, Ca2+, high reproducibility, and repeatability with RSD of 2.3 %. The Au NDs@FCF electrode demonstrates outstanding electrocatalytic oxidation and a rapid sensing response time of similar to 3 s. The current Au NDs@FCF electrode achieving the successful detection of L-Cys in practical human serum and urine samples highlights its potential application in biomedical diagnostics. This advancement indicates that the sensor can effectively operate in real-world conditions, offering a valuable tool for medical professionals to monitor L-Cys levels in patients accurately.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biochemical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Elancheziyan, Mari photo

Elancheziyan, Mari
College of Engineering (Department of Chemical and Biochemical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE