Cervical spine lateral radiograph versus whole spine lateral radiograph A retrospective comparative study to identify a better modality to assess cervical sagittal alignmentopen access
- Authors
- Lee, Dong-Ho; Park, Sehan; Kim, Dong Gyun; Hwang, Chang Ju; Lee, Choon Sung; Hwang, Eui Seung; Cho, Jae Hwan
- Issue Date
- 28-May-2021
- Publisher
- LIPPINCOTT WILLIAMS & WILKINS
- Keywords
- cervical lateral radiograph; cervical sagittal alignment; T1 slope; whole spine lateral radiograph
- Citation
- MEDICINE, v.100, no.21, pp E25987
- Indexed
- SCIE
SCOPUS
- Journal Title
- MEDICINE
- Volume
- 100
- Number
- 21
- Start Page
- E25987
- URI
- https://scholarworks.dongguk.edu/handle/sw.dongguk/4958
- DOI
- 10.1097/MD.0000000000025987
- ISSN
- 0025-7974
1536-5964
- Abstract
- This study is aimed to compare whole-spine lateral radiograph (WLR) and cervical lateral radiograph (CLR) in terms of T1 slope visibility and cervical sagittal parameters and to identify the superior imaging modality for assessment of cervical sagittal parameters. We retrospectively reviewed the radiographic data of 60 consecutive adult patients (male-to-female ratio, 38:22; mean age, 5 5. 6 +/- 1. 3 years) who presented with only neck pain (without radiculopathy or myelopathy). All the patients underwent standing CLR and WLR. The following parameters were measured and analyzed: 1. T1 slope visibility, 2. T1 slope, 3. C7 slope, 4. C0-C2 Cobb angle (CAC0-C2), 5. C2-C7 Cobb angle (CAC2-C7), and 6. cervical sagittal vertical axis (cSVA). The visibility of the T1 slope was significantly lower with WLR than with CLR (28.3% vs 8 3. 3%, P = .049). The mean CAC2-C7 on WLR was significantly less lordotic than that on CLR (1 1. 2 +/- 9.2 degrees vs 1 4. 3 +/- 1 1. 3 degrees; P = .01). The mean cSVA was translated more posteriorly on WLR than on CLR (9.9 +/- 18.9 mm vs 1 5. 0 +/- 1 3. 4 mm, P = .04). However, no significant differences in T1 slope, C7 slope, and CAC0-C2 were found between CLR and WLR. This study shows that standing CLR could provide better visualization of the upper endplate of T 1. Furthermore, WLR taken in hands on clavicle position distorted radiographic measurements such as CAC2-C7 and cSVA. Therefore, CLR performed in the standing position seems to allow more-accurate measurements of cervical sagittal parameters.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - Graduate School > Department of Medicine > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.