Detailed Information

Cited 14 time in webofscience Cited 14 time in scopus
Metadata Downloads

Flexible and patterned-free Ni/NiO-based temperature device on cylindrical PET fabricated by RF magnetron sputtering: Bending and washing endurance tests

Authors
Appiagyei, Alfred BekoeBanua, JomarisHan, Jeong In
Issue Date
25-Aug-2021
Publisher
ELSEVIER SCIENCE INC
Keywords
RF sputtering; Flexible PET substrate; Ni/NiO bilayer; Temperature coefficient of resistance; Bending; Washing
Citation
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, v.100, pp 372 - 382
Pages
11
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY
Volume
100
Start Page
372
End Page
382
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/4572
DOI
10.1016/j.jiec.2021.04.058
ISSN
1226-086X
1876-794X
Abstract
Flexible Resistive Temperature Detectors (RTDs) based on metal thin film have broad application prospects in smart clothes, however, they are constructed with patterned metal films using complicated manufacturing processes. Herein, we report a simple radio frequency (RF) magnetron sputtering method to fabricate light-weight, inexpensive and flexible temperature sensors (TS), whose sensitive materials act as electrode itself composed of Ni, NiO and Ni/NiO bilayer thin films. The Ni/NiO bilayer TS could be bent in different radius with resistance change below 5% signifying high flexibility. Fabricated Ni/NiO bilayer TS exhibited superior sensing performance with temperature coefficient of resistance (TCR) of 3.8 x 10 (3) degrees C (1) compared to 3.2 x 10( 3) degrees C (1) and 3.1 x 10 (3) degrees C (1) for Ni and NiO thin films respectively. It showed a linear response with R 2 -value of 0.9852. The Ni/NiO bilayer TS showed TCR of 1.0 x 10 (4) degrees C (1) even after 16,000 repetitive mechanical bends. Ni/NiO temperature sensor maintains high TCR towards exposure to different chemical solutions (acid, alkaline, detergents). The easy-fabrication process with good surface condition, together with the demonstrated results, suggest Ni/NiO is a promising candidate for flexible RTD device. (C) 2021 The Korean Society of Industrial and Engineering Chemistry. Published by Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biochemical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE