Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Triple-Element Back-to-Back Transducer With 3D Printed Housing for Intravascular Ultrasound Imaging: A Feasibility Studyopen access

Authors
Lee, Hee SuJeong, Jong Seob
Issue Date
2022
Publisher
IEEE
Keywords
Acoustics; Finite element analysis; Spatial resolution; Three-dimensional displays; Transducers; Ultrasonic imaging; Wires
Citation
IEEE Access, v.10, pp 9287 - 9297
Pages
11
Indexed
SCIE
SCOPUS
Journal Title
IEEE Access
Volume
10
Start Page
9287
End Page
9297
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/3806
DOI
10.1109/ACCESS.2022.3144604
ISSN
2169-3536
2169-3536
Abstract
Intravascular ultrasound (IVUS) can provide a high-resolution cross-sectional image of the blood vessel to detect the plaque morphology. The resolution of the IVUS image is proportional to a center frequency, however, a penetration depth decreases accordingly. To compensate for this problem, in this study, we propose the triple-element IVUS transducer capable of selecting an operating frequency according to the desired imaging area. In the proposed transducer, three-piezoelectric layers of 10 MHz, 20 MHz, and 30 MHz are formed on the top and both sides of the cube-shaped acoustic stack. These active layers share a common backing layer connected to one co-axial cable and can be driven simultaneously. In order to facilitate the manufacture process of the proposed IVUS transducer, split-assembling fabrication technique and a 3D printed housing with patterned electrodes were employed. The design specifications of the transducer were determined based on finite element analysis (FEA) simulation, and the prototype transducer was fabricated for feasibility study. The successful operation of individual elements constituting the proposed transducer was verified through B-mode imaging experiments using wire and tissue-mimicking phantoms. Subsequently, as a result of performing frequency compounding by combining two and three fundamental images, it was confirmed that the CNR (Contrast-to-Noise) value was improved by about 44-77. Therefore, the proposed IVUS transducer is expected to be one of the useful methods for diagnosing vascular diseases. © 2022 Institute of Electrical and Electronics Engineers Inc.. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jong Seob photo

Jeong, Jong Seob
College of Life Science and Biotechnology (Department of Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE