dc.description.abstractThis study quantified six heavy metals (Pb, Cd, As, Sn, Hg, and Me-Hg) in home meal replacement products. Satisfactory linearity (R-2 > 0.99), recovery (80.65-118.02%), limits of detection (0.02-2.81 mu g/kg), limits of quantification (0.05-8.51 mu g/kg), accuracy (80.49-119.87%), precision (0.26-14.93%), standard uncertainty (0.082-0.321%) and relative standard uncertainty (0.084-0.320%) of the six heavy metals were obtained. The average concentration of the six heavy metals was 8.87 mu g/kg. Heavy metal concentrations were converted to food intake data of 0.009 mu g/kg to recalculate the 95th percentile food intake data (g/day) of individual heavy metals. These were then divided by age group to evaluate the average exposure to heavy metals and determine the 95th percentile of exposure from daily intake and for the whole population, of home meal replacement products. The chronic daily intake amount of six heavy metals was 1.60 x 10(-2) mu g/kg/day. Based on total chronic daily intake values, the risk and margin of exposure of each of the heavy metals was 9.13 x 10(7), demonstrating that intake associated with home meal replacement products is negligible.-
dc.format.extent13-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleRisk Assessment and Determination of Heavy Metals in Home Meal Replacement Products by Using Inductively Coupled Plasma Mass Spectrometry and Direct Mercury Analyzer-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/foods11040504-
dc.identifier.scopusid2-s2.0-85124744926-
dc.identifier.wosid000806175300001-
dc.identifier.bibliographicCitationFoods, v.11, no.4, pp 1 - 13-
dc.citation.titleFoods-
dc.citation.volume11-
dc.citation.number4-
dc.citation.startPage1-
dc.citation.endPage13-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaFood Science & Technology-
dc.relation.journalWebOfScienceCategoryFood Science & Technology-
dc.subject.keywordPlusHEALTH-RISKS-
dc.subject.keywordPlusFOOD CROPS-
dc.subject.keywordAuthorhome meal replacement-
dc.subject.keywordAuthorheavy metal-
dc.subject.keywordAuthorinductively coupled plasma mass spectrometry-
dc.subject.keywordAuthordirect mercury analyzer-
dc.subject.keywordAuthorrisk assessment-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Food Science & Biotechnology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Han Seung photo

Shin, Han Seung
College of Life Science and Biotechnology (식품바이오융합공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE