Emergency rescue stent grafting for a ruptured degenerated graft that bypassed coarctation of the aorta: a case reportopen access
- Authors
- 최진호; 최민석; Lee Haeyoung
- Issue Date
- Mar-2022
- Publisher
- 고신대학교 의과대학 학술지
- Keywords
- Case reports; Coarctation of aorta; Dacron; Endovascular procedures; Ruptured aortic aneurysm
- Citation
- 고신대학교 의과대학 학술지, v.37, no.1, pp 89 - 92
- Pages
- 4
- Indexed
- KCI
- Journal Title
- 고신대학교 의과대학 학술지
- Volume
- 37
- Number
- 1
- Start Page
- 89
- End Page
- 92
- URI
- https://scholarworks.dongguk.edu/handle/sw.dongguk/3498
- DOI
- 10.7180/kmj.21.047
- ISSN
- 2005-9531
2586-7024
- Abstract
- A 33-year-old man who had undergone bypass from the distal aortic arch to the proximal descending thoracic aorta with a Dacron graft to treat coarctation of the aorta 20 years prior presented to the emergency department with massive hemoptysis. He was diagnosed with a graft-to-bronchial fistula. After thoracic endovascular aneurysm repair through the coarctation, aortic replacement was performed 3 weeks later. Therefore, emergency-rescue thoracic endovascular aneurysm repair can be considered for preventing aortic rupture.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - Graduate School > Department of Medicine > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.