Detailed Information

Cited 7 time in webofscience Cited 12 time in scopus
Metadata Downloads

The medial window technique as a salvage method to insert C2 pedicle screw in the case of a high-riding vertebral artery or narrow pedicle: a technical note and case series

Authors
Lee, Dong-HoPark, SehanCho, Jae HwanHwang, Chang JuLee, Hyung RaeSeok, Sang YunLee, Choon Sung
Issue Date
May-2022
Publisher
Springer-Verlag GmbH Germany
Keywords
C2 medial window screw; Pedicle screw; High-riding vertebral artery; Narrow pedicle; Vertebral artery groove violation
Citation
European Spine Journal, v.31, no.5, pp 1251 - 1259
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
European Spine Journal
Volume
31
Number
5
Start Page
1251
End Page
1259
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/3237
DOI
10.1007/s00586-022-07146-6
ISSN
0940-6719
1432-0932
Abstract
Purpose To describe the safety and feasibility of C2 medial window screw (C2MWS) as an alternative salvage method for C2 pedicle screws in cases of high-riding vertebral artery (HRVA) or narrow pedicle. Methods The C2MWS technique involves screw insertion by intentionally breaching the medial cortex of the pedicle to avoid vertebral artery injury. Twelve patients who underwent C2 screw insertion via the C2MWS were retrospectively reviewed. C2MWS was indicated in cases of high-riding vertebral artery (HRVA) or narrow pedicle (pedicle width <= 4 mm). The width of the canal breach by screw, vertebral artery groove (VAG) breach, solid fusion, neck pain visual analogue scale (VAS) score, and Japanese Orthopedic Association (JOA) score were assessed as outcome measurements. Results C2MWS was indicated due to both HRVA and narrow pedicle for 11 screws, narrow pedicle for one screw, and HRVA for two screws. No screw VAG breach or vertebral artery injury was noted postoperatively. The mean width of canal breach was 2.9 +/- 1.3 mm. There were no cases demonstrating neurologic deterioration, and 11 patients (91.7%) demonstrated solid fusion at 1-year follow-up. Furthermore, neck pain VAS and JOA scores significantly improved after the surgery. Conclusions The C2MWS technique can provide 3-column fixation while reliably avoiding VA injury. C2MWS could be considered as a salvage alternative method when the insertion of C2 pedicle screw is complicated by HRVA or a narrow pedicle, while there is a need to provide firmer fixation strength than that provided by pars or translaminar screws.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE