Detailed Information

Cited 30 time in webofscience Cited 35 time in scopus
Metadata Downloads

Highly stable and conductive PEDOT:PSS/graphene nanocomposites for biosensor applications in aqueous medium

Authors
Liu, DongtaoRahman, Md. MahbuburGe, ChuangyeKim, JaecheonLee, Jae-Joon
Issue Date
21-Dec-2017
Publisher
ROYAL SOC CHEMISTRY
Citation
NEW JOURNAL OF CHEMISTRY, v.41, no.24, pp 15458 - 15465
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
NEW JOURNAL OF CHEMISTRY
Volume
41
Number
24
Start Page
15458
End Page
15465
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/25490
DOI
10.1039/c7nj03330c
ISSN
1144-0546
1369-9261
Abstract
In this article, we demonstrated the development of highly water-stable and conductive poly(3,4-ethylene-dioxythiophene): poly(styrene sulfonate) (PEDOT:PSS)/graphene nanoplatelet (GNP) [PPG] composites on a fluorine-doped tin oxide (FTO) electrode for the detection of dopamine (DA) in the presence of ascorbic acid (AA) and uric acid (UA) in aqueous medium. PPG was deposited on FTO via the electrospray technique from a mixture solution of PEDOT: PSS and GNPs, which was subsequently treated with sulfuric acid (H2SO4, 98%). Acid treatment enabled stabilisation of the GNPs on FTO in water, due to the removal of insulating and hydrophilic PSS (68%) from the composites, and concurrently increased the conductivity (105 S cm(-1)), owing to the presence of a high percentage of hydrophobic and conductive PEDOT, as well as strong pi-pi interactions between PEDOT and GNPs. The untreated PPG electrode exhibited low water stability of GNPs and low conductivity (23 S cm(-1)). Accordingly, the acid-treated PPG/FTO electrode showed very high electrochemical stability, low charge transfer resistance (Rct) at the electrode7electrolyte interface, and improved catalytic activity for the oxidation of DA in aqueous buffer solution with very high sensitivity. It showed sufficiently high anodic peak-to-peak potential separations (Delta E-pa) between DA and AA (0.27 V) and DA and UA (0.11 V) for the interference-free detection of DA with a detection limit (S/N = 3) and sensitivity of similar to 105 nM and 27.7 mu A mu M-1 cm(-2), respectively.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Energy and Materials Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jae Joon photo

Lee, Jae Joon
College of Engineering (Department of Energy and Materials Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE