Detailed Information

Cited 6 time in webofscience Cited 8 time in scopus
Metadata Downloads

Basal buffer systems for a newly glycosylated recombinant human interferon-beta with biophysical stability and DoE approaches

Authors
Kim, Nam AhSong, KyoungLim, Dae GonHada, ShavronShin, Young KeeShin, SangmunJeong, Seong Hoon
Issue Date
Oct-2015
Publisher
ELSEVIER SCIENCE BV
Keywords
Interferon; Design of experiment (DoE); Differential Scanning Calorimetry (DSC); FT-IR; Protein formulation; Biobetter
Citation
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, v.78, pp 177 - 189
Pages
13
Indexed
SCI
SCIE
SCOPUS
Journal Title
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES
Volume
78
Start Page
177
End Page
189
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/25288
DOI
10.1016/j.ejps.2015.07.020
ISSN
0928-0987
1879-0720
Abstract
The purpose of this study was to develop a basal buffer system for a biobetter version of recombinant human interferon-beta la (rhIFN-beta la), termed R27T, to optimize its biophysical stability. The protein was pre-screened in solution as a function of pH (2-11) using differential scanning calorimetry (DSC) and dynamic light scattering (DLS). According to the result, its experimental pI and optimal pH range were 5.8 and 3.6-4.4, respectively. Design of experiment (DoE) approach was developed as a practical tool to aid formulation studies as a function of pH (2.9-5.7), buffer (phosphate, acetate, citrate, and histidine), and buffer concentration (20 mM and 50 mM). This method employed a weight-based procedure to interpret complex data sets and to investigate critical key factors representing protein stability. The factors used were T-m, enthalpy, and relative helix contents which were obtained by DSC and Fourier Transform Infrared spectroscopy (FT-IR). Although the weights changed by three responses, objective functions from a set of experimental designs based on four buffers were highest in 20 mM acetate buffer at pH 3.6 among all 19 scenarios tested. Size exclusion chromatography (SEC) was adopted to investigate accelerated storage stability in order to optimize the pH value with susceptible stability since the low pH was not patient-compliant. Interestingly, relative helix contents and storage stability (monomer remaining) increased with pH and was the highest at pH 4.0. On the other hand, relative helix contents and thermodynamic stability decreased at pH 4.2 and 4.4, suggesting protein aggregation issues. Therefore, the optimized basal buffer system for the novel biobetter was proposed to be 20 mM acetate buffer at pH 3.8 +/- 0.2. (C) 2015 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > Department of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE