Detailed Information

Cited 15 time in webofscience Cited 14 time in scopus
Metadata Downloads

Highly electrochemically active Ti3C2Tx MXene/MWCNT nanocomposite for the simultaneous sensing of paracetamol, theophylline, and caffeine in human blood samples

Authors
Mari, ElancheziyanDuraisamy, MurugesanEswaran, MuthusankarSellappan, SenthilkumarWon, KeehoonChandra, PranjalTsai, Pei-ChienHuang, Po-ChinChen, Yi-HsunLin, Yuan-ChungPonnusamy, Vinoth Kumar
Issue Date
Apr-2024
Publisher
Springer Verlag
Keywords
MXene/MWCNT; Non-enzymatic electrochemical sensor; Differential pulse voltammetry; Paracetamol; Caffeine; Theophylline; Human blood sample
Citation
Microchimica Acta, v.191, no.4
Indexed
SCIE
SCOPUS
Journal Title
Microchimica Acta
Volume
191
Number
4
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/21552
DOI
10.1007/s00604-024-06273-9
ISSN
0026-3672
1436-5073
Abstract
The facile fabrication is reported of highly electrochemically active Ti(3)C(2)Tx MXene/MWCNT (3D/1D)-modified screen-printed carbon electrode (SPE) for the efficient simultaneous electrochemical detection of paracetamol, theophylline, and caffeine in human blood samples. 3D/1D Ti(3)C(2)Tx MXene/MWCNT nanocomposite was synthesized using microwave irradiation and ultrasonication processes. Then, the Ti(3)C(2)Tx/MWCNT-modified SPE electrode was fabricated and thoroughly characterized towards its physicochemical and electrochemical properties using XPS, TEM, FESEM, XRD, electrochemical impedance spectroscopy, cyclic voltammetry, and differential pulse voltammetry techniques. As-constructed Ti(3)C(2)Tx-MWCNT/SPE offers excellent electrochemical sensing performance with good detection limits (0.23, 0.57, and 0.43 mu M) and wide linear ranges (1.0 similar to 90.1, 2.0 similar to 62.0, and 2.0-90.9 mu M) for paracetamol, caffeine, and theophylline, respectively, in the human samples. Notably, the non-enzymatic electroactive nanocomposite-modified electrode has depicted a semicircle Nyquist plot with low charge transfer resistance (R-ct similar to 95 Omega), leading to high ionic diffusion and facilitating an excellent electron transfer path. All the above results in efficient stability, reproducibility, repeatability, and sensitivity compared with other reported works, and thus, it claims its practical utilization in realistic clinical applications.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biochemical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Won, Kee Hoon photo

Won, Kee Hoon
College of Engineering (Department of Chemical and Biochemical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE