Detailed Information

Cited 5 time in webofscience Cited 4 time in scopus
Metadata Downloads

Taking Oral Sulfate Tablets with Simethicone for Bowel Preparation Leads to Higher Adenoma Detection Rate than Polyethylene Glycol: A Propensity Score Analysis

Authors
Lee, Seung EunOh, Dong JunNam, Ji HyungCho, HyekiKim, Jae HakLee, Jun KyuLim, Yun JeongKoh, Moon SooKim, Sang Hoon
Issue Date
Mar-2023
Publisher
SPRINGER
Keywords
Colonoscopy; Propensity score analysis; Oral sulfate tablet; Simethicone; Adenoma detection
Citation
Digestive Diseases and Sciences, v.68, no.3, pp 867 - 876
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
Digestive Diseases and Sciences
Volume
68
Number
3
Start Page
867
End Page
876
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/2126
DOI
10.1007/s10620-022-07611-8
ISSN
0163-2116
1573-2568
Abstract
Background Efficient bowel preparation is essential for preventing colorectal cancer by improving endoscopic adenoma detection. Tablet for bowel preparation containing sulfate salts, OSTs (oral sulfate tablets), has been developed and it is gaining more popularity. However, its efficacy compared to standard preparation agent, PEG-AA (polyethylene glycol), has not been well discovered. We assessed the efficacy of PEG and OSTs using a real-time clinical data warehouse (CDW) model. Methods We performed a propensity score-matched (PSM) analysis of consecutive adult patients undergoing colonoscopy who received PEG-AA or OSTs prior to colonoscopy at a tertiary academic hospital. The endoscopic records of 992 adult patients were retrospectively analyzed. The clinical data warehouse collected data including bowel preparation, insertion time, observation time, and the detection of polyps and adenomas. Multivariate regression analysis was performed to reveal the factors associated with endoscopic outcomes. Results Among 992 patients included in the study, 770 and 222 patients received PEG-AA and OSTs, respectively. Among the propensity score-matched population (n = 1897), OSTs resulted in better bowel cleansing quality (8.16 vs 7.84, p = 0.014) and a higher adenoma detection rate (38.6% vs 27.1%, p = 0.003). Using PEG-AA, older age, inadequate bowel preparation (BBPS score < 6) and endoscopy by fellows were found to be factors associated with poor adenoma detection. In the elderly over 65 years of age, a significant difference in cleansing quality between the two groups (7.21 vs 8.19, p < 0.001) was found, but its impact on ADR was not prominent (49.5% vs 45.4%, p = 0.653). Conclusions OSTs with simethicone achieved better endoscopic cleanliness, improving adenoma detection rate compared to the conventional PEG-AA protocol. The synergistic effect of both the convenience of taking tablets and the reduction of intraluminal bubble by adjunctive simethicone improves the clinical efficacy of colonoscopy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Seung Eun photo

Lee, Seung Eun
Graduate School (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE