Detailed Information

Cited 9 time in webofscience Cited 10 time in scopus
Metadata Downloads

Intravascular Ultrasound Transducer by Using Polarization Inversion Technique for Tissue Harmonic Imaging: Modeling and Experiments

Authors
Sung, Jin HoJeong, Eun YoungJeong, Jong Seob
Issue Date
Dec-2020
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Transducers; Bandwidth; Mathematical model; Ultrasonic imaging; Harmonic analysis; Imaging; Impedance; High-frequency ultrasound image; intravascular ultrasound (IVUS) transducer; polarization inversion technique (PIT); tissue harmonic imaging (THI)
Citation
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.67, no.12, pp 3380 - 3391
Pages
12
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume
67
Number
12
Start Page
3380
End Page
3391
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/19498
DOI
10.1109/TBME.2020.2986284
ISSN
0018-9294
1558-2531
Abstract
Intravascular ultrasound (IVUS) tissue harmonic imaging (THI) is a useful vessel imaging technique that can provide deep penetration depth as well as high spatial and contrast resolution. Typically, a high-frequency IVUS transducer for THI requires a broad bandwidth or dual-frequency bandwidth. However, it is very difficult to make an IVUS transducer with a frequency bandwidth covering from the fundamental frequency to the second harmonic or a dual-peak at the desired frequency. To solve this problem, in this study, we applied the polarization inversion technique (PIT) to the IVUS transducer for THI. The PIT makes it relatively easy to design IVUS transducers with suitable frequency characteristics for THI depending on the inversion ratio of the piezoelectric layer and specifications of the passive materials. In this study, two types of IVUS transducers based on the PIT were developed for THI. One is a front-side inversion layer (FSIL) transducer with a broad bandwidth, and the other is a back-side inversion layer (BSIL) transducer with a dual-frequency bandwidth. These transducers were designed using finite element analysis (FEA)-based simulation, and the prototype transducers were fabricated. Subsequently, the performance was evaluated by not only electrical impedance and pulse-echo response tests but also B-mode imaging tests with a 25 mu m tungsten wire and tissue-mimicking gelatin phantoms. The FEA simulation and experimental results show that the proposed scheme can successfully implement the tissue harmonic IVUS image, and thus it can be one of the promising techniques for developing IVUS transducers for THI.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jong Seob photo

Jeong, Jong Seob
College of Life Science and Biotechnology (Department of Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE