Detailed Information

Cited 36 time in webofscience Cited 44 time in scopus
Metadata Downloads

Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantationopen access

Authors
Tchah, HungwonNam, KiyeunYoo, Aeri
Issue Date
18-Feb-2017
Publisher
IJO PRESS
Keywords
rotationally asymmetric multifocal intraocular lens; pupil center; photic phenomena; dysphotopsia; kappa angle; pupil center shift
Citation
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, v.10, no.2, pp 241 - 245
Pages
5
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY
Volume
10
Number
2
Start Page
241
End Page
245
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/17976
DOI
10.18240/ijo.2017.02.10
ISSN
2222-3959
2227-4898
Abstract
AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive, rotationally asymmetric, multifocal intraocular lenses (MIOLs). METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery, followed by implantation of rotationally asymmetric MIOLs were included. Distance and near visual acuity outcomes, intraocular aberrations, preferred reading distances, preoperative and postoperative refractive errors, mesopic and photopic pupil diameters, and the mesopic and photopic kappa angles were assessed. Patients were also administered a satisfaction survey. Photic phenomena were graded by questionnaire. Independent-related factors were identified by correlation and bivariate logistic regression analyses. RESULTS: The distance from the photopic to the mesopic pupil center (pupil center shift) was significantly associated with glare/halo symptoms [odds ratio (OR)=2.065, 95% confidence interval (CI)=0.916-4.679, P=0.006] and night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007). The preoperative photopic angle kappa was significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041). The photopic angle kappa was also significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041) and with night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007) in patients implanted with rotationally asymmetric MIOLs. " CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis (angle kappa) may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Nam, Ki Yeun photo

Nam, Ki Yeun
Graduate School (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE