Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of the GlideRite to the Conventional-malleable-stylet for Endotracheal Intubation by the Macintosh-laryngoscope: A Simulation Study Using ManekinsComparison of the GlideRite to the Conventional-malleable-stylet for Endotracheal Intubation by the Macintosh-laryngoscope: A Simulation Study Using Manekins

Other Titles
Comparison of the GlideRite to the Conventional-malleable-stylet for Endotracheal Intubation by the Macintosh-laryngoscope: A Simulation Study Using Manekins
Authors
공용택이현정나지웅신동혁한상국이정훈최필조
Issue Date
Jun-2016
Publisher
대한응급의학회
Keywords
Instrumentation; Intubation intratracheal; Manekins
Citation
대한응급의학회지, v.27, no.3, pp 246 - 253
Pages
8
Indexed
KCI
Journal Title
대한응급의학회지
Volume
27
Number
3
Start Page
246
End Page
253
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/17169
ISSN
1226-4334
Abstract
Purpose: The purpose of this study is to compare the effectiveness of the GlideRite with the conventional-malleable- stylet (CMS) in endotracheal intubation (ETI) using the Macintosh-laryngoscope. Methods: This study is a randomized crossover simulation study. Participants performed ETI using both the GlideRite and the CMS in the normal airway and in a tongue edema (simulated difficult airway resulting in lower percentage of glottis opening [POGO]) model. Results: In both the normal and the tongue edema models, all 36 participants performed ETI successfully using the two stylets on the first attempt. In the normal airway model, there was no difference in time required for ETI (TETI) or ease of handling between the two stylets. In the tongue edema model, the TETI increased as POGO score decreased with the CMS (POGO score showing negative correlation with TETI for the CMS, Spearman’s rho=-0.518, p=0.001) but not for the GlideRite (rho=-0.208, p=0.224). The TETI was shorter with the GlideRite than the CMS, but without statistical significance (15.1 vs. 18.8 seconds, p=0.385). Ease of handling was superior with the GlideRite compared to the CMS (p=0.006). Conclusion: Performance of the GlideRite and the CMS was not different in the normal airway model. However, in the simulated difficult airway model with a low POGO score, the GlideRite performed better than the CMS for direct laryngoscopic intubation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jeong Hun photo

Lee, Jeong Hun
Graduate School (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE