댐 취수탑 3차원 내진안전성 평가에서의 동수압 적용방법에 관한 연구

Application of Hydrodynamic Pressure for Three­dimensional Earthquake Safety Analysis of Dam Intake Towers
  • 송광석
  • 민경욱
  • 배정주
  • 이지호

초록

In the present study, effective hydrodynamic pressure modeling methods for three-dimensional earthquake safety analysis of a dam intake tower structure are investigated. Time history analysis results using the Westergaard added mass and Chopra added mass methods are compared with the one by the CASI (Coupled Acoustic Structural Interaction) method, which is accepted as giving almost exact solutions, to evaluate the difference in displacement response, stress and dynamic eccentricity. The 3D time history analysis of a realistic intake tower, which has the standard geometry widely used in Korea, shows that the Chopra added mass method gives similar results in displacement and stress and less conservative results in dynamic eccentricity to CASI ones, while the Westergaard added mass yields much more conservative results in all measures. This study suggests to use the CASI method directly for three-dimensional earthquake safety analysis of a dam intake tower, if computationally possible.

키워드

Earthquake safetyIntake towerHydrodynamic pressureAdded massFluid-structure interactionAcoustic element
제목
댐 취수탑 3차원 내진안전성 평가에서의 동수압 적용방법에 관한 연구
제목 (타언어)
Application of Hydrodynamic Pressure for Three­dimensional Earthquake Safety Analysis of Dam Intake Towers
저자
송광석민경욱배정주이지호
DOI
10.5000/EESK.2018.22.3.139
발행일
2018-04
저널명
한국지진공학회논문집
22
3
페이지
139 ~ 147