Experimental Investigation on Heating Performance and Frosting Behavior of an Integrated R290 Secondary Loop Heat Pump

Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Energy storage batteries require strict thermal management due to temperature sensitivity, operating optimally within a narrow thermal range. Simultaneously, control rooms demand stable and comfortable ambient conditions for staff staying long-term. Conventional temperature control systems typically employ isolated solutions, resulting in functional fragmentation and inefficient resource utilization. To address these challenges, this study proposes and implements an integrated R290 secondary loop heat pump air-conditioning system designed to simultaneously manage the thermal environments of both energy storage batteries and control rooms. By adopting a secondary-loop coupling architecture, all thermal regulation is achieved indirectly via indirect heat transfer with a circulating ethylene glycol-based coolant, eliminating the risk of direct refrigerant (R290) exposure in occupied spaces and enhancing safety. The system supports multiple operational modes, enabling flexible and efficient dual-zone climate control. The heating performance—evaluated in terms of heat exchange capacity and coefficient of performance (COP)—is analyzed under varying ambient temperatures and compressor speeds. Additionally, the frosting behavior of the outdoor heat exchanger and its impact on heat transfer and system performance are examined. Results showed heat output ranged from 3.01 to 4.27 kW, and COP varied between 1.9 and 2.8. Ambient temperature (more dominant than compressor speed) and speed both affected performance: higher speed/warmer temperatures improved heat transfer efficiency; low temperatures accelerated frosting (e.g., −5°C reduced heat output by 19.67% and COP by 31.13%, vs. 13.72% and 12.40% at 5°C). These findings provide critical insights for optimizing heat transfer design and operation of integrated thermal management systems in energy storage facilities. Copyright © 2026 The Authors.

키워드

control roomCOPenergy storage batteryfrosting characteristicsheating performanceR290 secondary loop
제목
Experimental Investigation on Heating Performance and Frosting Behavior of an Integrated R290 Secondary Loop Heat Pump
저자
Chen, ZebingWang, YangWu, HongZhao, WenbinYan, JinjunPeng, LuyaoZhao, YugangWang, ZilongLi, KangMeibodi, Saleh S.Moosazadeh, MohammadMohtaram, Soheil
DOI
10.32604/fhmt.2026.077274
발행일
2026
유형
Article
저널명
Frontiers in Heat and Mass Transfer
24
2
페이지
1 ~ 18