상세 보기
Temporal Hollowing Augmentation With Polyetheretherketone Patient-Specific Implant
- Doh, GyeongHyeon;
- Eo, SuRak;
- Hong, Ki Yong
Citations
WEB OF SCIENCE
10Citations
SCOPUS
11초록
Temporal hollowing is a common complication of surgical dissection in the temporal region. As it is a serious cosmetic problem, the need for reconstruction is increasing. Advances in medical imaging, computer software, 3-dimensional printing technology, and biochemistry have enabled surgeons to use patient-specific implants for correction of craniofacial deformities. Titanium, polymethylmethacrylate, and polyetheretherketone are representative materials of the alloplastic implant. In this article, the authors report the first case of temporal hollowing augmentation using a polyetheretherketone patient-specific implant.
키워드
Temporal hollowing augmentation; polyetheretherketone patient-specific implant; alloplastic implant; PEEK CRANIOPLASTY; PREVENTS
- 제목
- Temporal Hollowing Augmentation With Polyetheretherketone Patient-Specific Implant
- 저자
- Doh, GyeongHyeon; Eo, SuRak; Hong, Ki Yong
- 발행일
- 2019-10
- 유형
- Article
- 권
- 30
- 호
- 7
- 페이지
- 2131 ~ 2133
- 언어
- ENG
- 출판사
- LIPPINCOTT WILLIAMS & WILKINS
- 발행국가
- 미국
- 분량
- 3 페이지
- ISSN
- E 1536-3732
P 1049-2275