Feasibility of Drone-Mounted Camera for Real-Time MA-rPPG in Smart Mirror Systems
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Featured Application A feasibility-stage experimental platform for evaluating real-time moving-average remote photoplethysmography (MA-rPPG) using a drone-mounted sensing assistant integrated with a smart mirror interface for flexible, contactless physiological monitoring. A previously validated smart mirror system is reused as a unified visualization and synchronization frontend, enabling controlled laboratory data acquisition and compared with MA-rPPG measurements obtained from a fixed desktop camera setup using the same model.Abstract Remote photoplethysmography (rPPG) enables contactless estimation of cardiovascular signals from video, but most existing studies assume a fixed, stationary camera. This study investigates the feasibility of performing real-time moving-average rPPG (MA-rPPG) using a drone-mounted camera, where platform motion, vibration, and viewing distance introduce additional challenges. Building on our previously validated real-time MA-rPPG smart mirror platform, we reuse the smart mirror interface as a unified frontend for visualization, synchronization, and logging while adapting the MA-rPPG pipeline to operate on live video streamed from an off-the-shelf DJI Tello micro-drone. Feasibility experiments were conducted with 10 participants under controlled indoor lighting and constrained flight conditions, where the drone maintained a stable hover in front of a standing subject and facial video was processed in real time to estimate heart rate from a forehead region of interest. To avoid cross-modality bias and clarify the effect of the aerial imaging platform, drone-derived MA-rPPG outputs were compared against a fixed desktop-camera MA-rPPG reference using the same trained model, enabling a controlled, like-for-like evaluation. The results indicate that continuous heart-rate estimation from a drone camera is feasible in our controlled hover-only setup, while agreement tended to vary with hover stability and effective facial resolution. This work is presented strictly as a feasibility-stage investigation and does not claim clinical validity. The findings provide an experimental baseline and operating-envelope insight for future motion-robust rPPG on mobile and aerial health-sensing platforms.

키워드

drone-mounted cameraremote photoplethysmography (rPPG)moving-average rPPG (MA-rPPG)contactless heart-rate monitoringunmanned aerial vehicle (UAV)smart mirror interfacefeasibility studyreal-time physiological sensing
제목
Feasibility of Drone-Mounted Camera for Real-Time MA-rPPG in Smart Mirror Systems
저자
Kasno, Mohammad AfifChoi, Yong-SikJung, Jin-Woo
DOI
10.3390/app16052307
발행일
2026-02
유형
Article
저널명
Applied Sciences
16
5
페이지
1 ~ 17