상세 보기
Constraint-aware thermoelectric generator design for small internal combustion engines: a high-fidelity framework from thermal-choke mechanisms to fleet-scale CO2 mitigation
- Zhang, Jiayu;
- Pan, Jinxiong;
- Jafaripournimchahi, Ammar;
- Meibodi, Saleh S.;
- Su, MingXu;
- ... Moosazadeh, Mohammad;
- 외 2명
WEB OF SCIENCE
0SCOPUS
0초록
Small internal combustion engines (≤50 kW) reject over 55% of fuel energy as exhaust heat, yet practical thermoelectric generator (TEG) deployment remains hindered by packaging constraints, strict back-pressure limits, and modeling approaches that rely on idealized thermal boundaries. This study presents a high-fidelity framework, validated experimentally with single-module and three-module-array prototype tests, for constraint-aware TEG design and system-level optimization. Temperature-dependent Bi₂Te₃ property correlations reduce modeling errors from 4.3% to <1.5%, while an analytical solution for trapezoidal legs reveals a thermal-choke mechanism and enables a converging-leg geometry that the model predicts will recover an additional 24.2 K temperature gradient at the array level. A semi-analytical system closure with convective, contact and radiative boundaries shows that the power-optimal array has an effective thermal resistance equal to the total external resistance. Multi-objective optimization under coupled back-pressure (≤5 kPa) and volume constraints yields a Pareto-optimal design delivering 13.61 W (model prediction at the 400 °C, 0.05 kg s−1 rated point; 12.74 W measured on the prototype array) at 6.75% efficiency, outperforming uniform-leg baselines by 10.5%. Prototype testing (single module at 250 and 350 °C; three-module array at 400 and 450 °C) confirms power-prediction accuracy within 6.8% (the model slightly over-predicts, mainly through the hot-side temperature difference; hot-side temperatures deviate by 7–11 K, above the 5 K target), with Monte Carlo propagation of input uncertainties giving ±16.2% power variability (a quantity separate from the measured deviation). Transient simulation over the WLTC Class 2 drive cycle for a representative 150 cc motorcycle platform demonstrates a cycle-averaged output of 6.8 W, a platform-specific finding indicating that rated-condition metrics can substantially overstate real-world annual energy recovery for duty cycles dominated by low-speed operation. Techno-economic assessment under a baseline capacity factor of 0.70 gives first-order, scenario-dependent estimates of a levelized cost of energy of 0.29–0.37 USD/kWh and an incremental payback period under one year for the γ = 1.3 upgrade (2.8–4.1 years for the complete unit), excluding maintenance, component-replacement and balance-of-plant costs, while scenario-based fleet-scale deployment analysis indicates a potential annual CO₂ mitigation of up to 2.9 Mt. (gross of the back-pressure fuel penalty, which can be of the same order as the recovered energy; Section 6.11) under full uptake across China's 350-million motorcycle fleet. The proposed framework bridges high-fidelity thermoelectric modeling with real-world exhaust energy recovery, offering a scalable pathway for decarbonizing compact engine platforms. © 2026 Published by Elsevier Ltd.
키워드
- 제목
- Constraint-aware thermoelectric generator design for small internal combustion engines: a high-fidelity framework from thermal-choke mechanisms to fleet-scale CO2 mitigation
- 저자
- Zhang, Jiayu; Pan, Jinxiong; Jafaripournimchahi, Ammar; Meibodi, Saleh S.; Su, MingXu; Li, Kang; Moosazadeh, Mohammad; Mohtaram, Soheil
- 발행일
- 2026-12
- 유형
- Article
- 권
- 181
- 페이지
- 1 ~ 20
- 언어
- ENG
- 출판사
- Elsevier Ltd
- 발행국가
- 네덜란드
- 분량
- 20 페이지
- ISSN
- E 1879-0178
P 0735-1933