Analytic Model of Four-switch Inverter-fed Driving System for Wye or Delta-connected Motor with Current Ripple Reduction Scheme

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

2

초록

This paper proposes an analytic model for four-switch inverter (FSI)-driven wye (Y) or delta (Delta)-connected motors with a current ripple reduction algorithm. FSIs employ four switches in controlling three-phase load instead of using six switches. They have split dc-link stage, and due to this inherent structure there exists the voltage difference between upper and lower capacitors, which results in distortion of the inverter output voltage. To study characteristics of FSIs, this paper presents an advanced simulation models of PSI-driven control system for 3-phase motor that can has a wire connection either Y or Delta. In addition, this paper introduces a current ripple reduction scheme that mitigates degradation of control performance due to the voltage difference between the dc-link capacitors. The validity of the proposed method and the analytic model is verified by simulations and experiments carried out with 1-HP induction machine with Y or Delta-connection

키워드

Simulation modelFour-Switch Inverter (PSI)Ripple compensationWye or delta-connected motorLINK VOLTAGE RIPPLE
제목
Analytic Model of Four-switch Inverter-fed Driving System for Wye or Delta-connected Motor with Current Ripple Reduction Scheme
저자
Lee, Dong-MyungJung, Jin-WooHeo, Seo WeonKim, Tae Heoung
DOI
10.5370/JEET.2016.11.1.109
발행일
2016-01
유형
Article
저널명
Journal of Electrical Engineering & Technology
11
1
페이지
109 ~ 116