초록
In this paper, a wearable resistive-type humidity sensor is fabricated on a cylindrical organic substrate for the first time. This sensor contained polyvinyl-alcohol (PVA) as the sensing material, which was applied by the dip-coating method at the middle, and copper (Cu) thin film was applied by RF magnetron sputtering for the side electrodes. The resistance was measured for 60-90%RH. Thus, the value was decreased by hydrogen bonds between the hydroxyl groups and water molecules in the highly humid condition. In addition, as the dip-coating speed and number of coats varied, corresponding factors a and 6, which were related to the activation energy, thickness, and/or conductance, were suggested based on Ohm's law and conductivity equations. Moreover, to verify its durability as a wearable computing device, repetitive bending tests were performed with different bending times and radii. (C) 2017 Elsevier B.V. All rights reserved.
키워드
- 제목
- Cylindrical relative humidity sensor based on poly-vinyl alcohol (PVA) for wearable computing devices with enhanced sensitivity
- 저자
- Jang, Ju Hee; Han, Jeong In
- 발행일
- 2017-07-01
- 유형
- Article; Proceedings Paper
- 권
- 261
- 페이지
- 268 ~ 273
- 언어
- ENG
- 출판사
- ELSEVIER SCIENCE SA
- 발행국가
- 스위스
- 분량
- 6 페이지
- ISSN
- P 0924-4247