Cited 86 time in
Metal-organic framework derived nanoporous carbon/Co3O4 composite electrode as a sensing platform for the determination of glucose and high-performance supercapacitor
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Haldorai, Yuvaraj | - |
| dc.contributor.author | Choe, Sang Rak | - |
| dc.contributor.author | Huh, Yun Suk | - |
| dc.contributor.author | Han, Young-Kyu | - |
| dc.date.accessioned | 2023-04-28T09:42:03Z | - |
| dc.date.available | 2023-04-28T09:42:03Z | - |
| dc.date.issued | 2018-02 | - |
| dc.identifier.issn | 0008-6223 | - |
| dc.identifier.issn | 1873-3891 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/9782 | - |
| dc.description.abstract | Here, we demonstrate the controlled synthesis of nanoporous carbon and cobalt oxide (NPC-Co3O4) composite from a single precursor source zeolitic imidazolate framework-67, which leads to some new interesting electrochemical properties. The composite shows an outstanding electrochemical performance for measuring the oxidation of glucose in alkaline solution. The differential pulse voltammetric response of the NPC-Co3O4 composite electrode for the sensing of glucose exhibits a linear relation with the concentration range of 5 x 10(-12)-2.05 x 10(-10) M and a low detection limit of 2 x 10 (-12) M. The fabricated sensor shows high sensitivity, reliable reproducibility, and good selectivity. The sensor, when used for the direct determination of glucose in blood serum samples, shows good recovery (98.5 -101.0%), suggesting its feasibility for biomedical applications. In addition, in a given potential range of 0 -1 V, the composite exhibits a high capacitance (885 F g(-1) at a current density of 2.5 A g(-1)) and long cycle life (similar to 94% capacitance retention after 10,000 cycles). (C) 2017 Elsevier Ltd. All rights reserved. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
| dc.title | Metal-organic framework derived nanoporous carbon/Co3O4 composite electrode as a sensing platform for the determination of glucose and high-performance supercapacitor | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.carbon.2017.11.022 | - |
| dc.identifier.scopusid | 2-s2.0-85034057465 | - |
| dc.identifier.wosid | 000417484000042 | - |
| dc.identifier.bibliographicCitation | CARBON, v.127, pp 366 - 373 | - |
| dc.citation.title | CARBON | - |
| dc.citation.volume | 127 | - |
| dc.citation.startPage | 366 | - |
| dc.citation.endPage | 373 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Physical | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
| dc.subject.keywordPlus | POROUS CARBON | - |
| dc.subject.keywordPlus | OXIDE HYBRID | - |
| dc.subject.keywordPlus | SENSOR | - |
| dc.subject.keywordPlus | NANOPARTICLES | - |
| dc.subject.keywordPlus | POLYMER | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
