Cited 105 time in
Model Predictive Control with Modulated Optimal Vector for a Three-Phase Inverter with an LC Filter
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Hoach The Nguyen | - |
| dc.contributor.author | Eun-Kyung Kim | - |
| dc.contributor.author | Ik-Pyo Kim | - |
| dc.contributor.author | Han Ho Choi | - |
| dc.contributor.author | Jin-Woo Jung | - |
| dc.date.accessioned | 2023-04-28T09:41:37Z | - |
| dc.date.available | 2023-04-28T09:41:37Z | - |
| dc.date.issued | 2018-03 | - |
| dc.identifier.issn | 0885-8993 | - |
| dc.identifier.issn | 1941-0107 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/9721 | - |
| dc.description.abstract | This paper proposes an effective model predictive control (MPC) scheme using a modulated optimal vector (MOV) and finite control options for a three-phase inverter with an LC filter. Unlike other MPC methods, the proposed MPC strategy exploits the unconstrained optimal vector (OV) of the continuous-control-set (CCS) MPC to limit the control options for the unconstrained mode. First, the analytical OV is derived based on a least-squares optimization. If the input constraints are not violated, the OV is applied with a space vector modulation (SVM) technique like the CCS-MPC. Otherwise, the OV is scaled into the MOV and only three control options are online evaluated to reselect the control input. Experiments are conducted on a three-phase inverter test bed with a TI TMS320F28335 digital signal processor to validate the improvements of the proposed method, especially the robust performances and fast responses. The comparative results with the FCS-MPC show the superior performances of the proposed scheme with smaller steady-state error and lower total harmonic distortion due to the analytical OV with SVM, more robustness to parameter uncertainties due to the disturbance observer, and faster dynamic response due to the online reselection of control inputs. | - |
| dc.format.extent | 14 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
| dc.title | Model Predictive Control with Modulated Optimal Vector for a Three-Phase Inverter with an LC Filter | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TPEL.2017.2694049 | - |
| dc.identifier.scopusid | 2-s2.0-85038934889 | - |
| dc.identifier.wosid | 000417819300071 | - |
| dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON POWER ELECTRONICS, v.33, no.3, pp 2690 - 2703 | - |
| dc.citation.title | IEEE TRANSACTIONS ON POWER ELECTRONICS | - |
| dc.citation.volume | 33 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 2690 | - |
| dc.citation.endPage | 2703 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.subject.keywordPlus | PWM INVERTER | - |
| dc.subject.keywordPlus | POWER-ELECTRONICS | - |
| dc.subject.keywordPlus | UPS APPLICATIONS | - |
| dc.subject.keywordPlus | CONVERTERS | - |
| dc.subject.keywordPlus | SYSTEMS | - |
| dc.subject.keywordPlus | SINGLE | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | TRANSIENT | - |
| dc.subject.keywordPlus | SCHEME | - |
| dc.subject.keywordAuthor | Finite control set (FCS) | - |
| dc.subject.keywordAuthor | model predictive control (MPC) | - |
| dc.subject.keywordAuthor | modulated optimal vector (MOV) | - |
| dc.subject.keywordAuthor | space vector modulation (SVM) | - |
| dc.subject.keywordAuthor | three-phase inverter | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.