Detailed Information

Cited 13 time in webofscience Cited 18 time in scopus
Metadata Downloads

Multifunctionalized Reduced Graphene Oxide Biosensors for Simultaneous Monitoring of Structural Changes in Amyloid-40open access

Authors
Jeong, DahyeKim, JinsikChae, Myung-SicLee, WonseokYang, Seung-HoonKim, YoungSooKim, Seung MinLee, Jin SanLee, Jeong HoonChoi, JungkyuYoon, Dae SungHwang, Kyo Seon
Issue Date
Jun-2018
Publisher
MDPI
Keywords
reduced graphene oxide(rGO); Alzheimer's disease; amyloid beta; biosensor
Citation
SENSORS, v.18, no.6
Indexed
SCIE
SCOPUS
Journal Title
SENSORS
Volume
18
Number
6
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/9464
DOI
10.3390/s18061738
ISSN
1424-8220
1424-3210
Abstract
Determination of the conformation (monomer, oligomer, or fibril) of amyloid peptide aggregates in the human brain is essential for the diagnosis and treatment of Alzheimer's disease (AD). Accordingly, systematic investigation of amyloid conformation using analytical tools is essential for precisely quantifying the relative amounts of the three conformations of amyloid peptide. Here, we developed a reduced graphene oxide (rGO) based multiplexing biosensor that could be used to monitor the relative amounts of the three conformations of various amyloid- 40 (A40) fluids. The electrical rGO biosensor was composed of a multichannel sensor array capable of individual detection of monomers, oligomers, and fibrils in a single amyloid fluid sample. From the performance test of each sensor, we showed that this method had good analytical sensitivity (1 pg/mL) and a fairly wide dynamic range (1 pg/mL to 10 ng/mL) for each conformation of A40. To verify whether the rGO biosensor could be used to evaluate the relative amounts of the three conformations, various amyloid solutions (monomeric A40, aggregated A40, and disaggregated A40 solutions) were employed. Notably, different trends in the relative amounts of the three conformations were observed in each amyloid solution, indicating that this information could serve as an important parameter in the clinical setting. Accordingly, our analytical tool could precisely detect the relative amounts of the three conformations of A40 and may have potential applications as a diagnostic system for AD.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jin Sik photo

Kim, Jin Sik
College of Life Science and Biotechnology (Department of Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE