Cited 29 time in
Allergen Microarrays for In Vitro Diagnostics of Allergies: Comparison with ImmunoCAP and AdvanSure
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jeon, Hyunjin | - |
| dc.contributor.author | Jung, Joo Hyun | - |
| dc.contributor.author | Kim, Yoonji | - |
| dc.contributor.author | Kwon, Youngeun | - |
| dc.contributor.author | Kim, Seon Tae | - |
| dc.date.accessioned | 2023-04-28T08:41:08Z | - |
| dc.date.available | 2023-04-28T08:41:08Z | - |
| dc.date.issued | 2018-07 | - |
| dc.identifier.issn | 2234-3806 | - |
| dc.identifier.issn | 2234-3814 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/9350 | - |
| dc.description.abstract | Background: In vitro detection of the allergen-specific IgE antibody (sIgE) is a useful tool for the diagnosis and treatment of allergies. Although multiple simultaneous allergen tests offer simple and low-cost screening methods, these platforms also have limitations with respect to multiplexibility and analytical performance. As an alternative assay platform, we developed and validated a microarray using allergen extracts that we termed " GOLD" chip. Methods: Serum samples of 150 allergic rhinitis patients were used in the study, and the diagnostic performance of the microarray was compared with that of AdvanSure (LG Life Sciences, Daejun, Korea) and ImmunoCAP (Phadia, Uppsala, Sweden). Standard IgE samples were used for the quantitative measurement of sIgEs. Results: The microarray-based assay showed excellent performance in the quantitative measurement of sIgEs, demonstrating a linear correlation within the range of sIgE concentrations tested. The limit of detection (LOD) was lower than 0.35 IU/mL, which is the current standard for the LOD cut-off. The assay also provided highly reproducible sets of data. The total agreement percentage of positive and negative calls was 92.2% compared with ImmunoCAP. Moreover, an outstanding correlation was observed between the microarray and the ImmunoCAP results, with Cohen's kappa and Pearson correlation coefficient values of 0.80 and 0.79, respectively. Conclusions: The microarray-based in vitro diagnostic platform offers a sensitive, reproducible, and highly quantitative method to detect sIgEs. The results showed strong correlations with that of ImmunoCAP. These results suggest that the new allergen microarray can serve as a useful alternative to current screening platforms, ultimately becoming a first-line screening method. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN SOC LABORATORY MEDICINE | - |
| dc.title | Allergen Microarrays for In Vitro Diagnostics of Allergies: Comparison with ImmunoCAP and AdvanSure | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3343/alm.2018.38.4.338 | - |
| dc.identifier.scopusid | 2-s2.0-85045214938 | - |
| dc.identifier.wosid | 000431125600008 | - |
| dc.identifier.bibliographicCitation | ANNALS OF LABORATORY MEDICINE, v.38, no.4, pp 338 - 347 | - |
| dc.citation.title | ANNALS OF LABORATORY MEDICINE | - |
| dc.citation.volume | 38 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 338 | - |
| dc.citation.endPage | 347 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Medical Laboratory Technology | - |
| dc.relation.journalWebOfScienceCategory | Medical Laboratory Technology | - |
| dc.subject.keywordPlus | COMPONENT-RESOLVED DIAGNOSIS | - |
| dc.subject.keywordPlus | IGE | - |
| dc.subject.keywordPlus | CHILDREN | - |
| dc.subject.keywordPlus | PROTEIN | - |
| dc.subject.keywordPlus | SKIN | - |
| dc.subject.keywordPlus | EXTRACT | - |
| dc.subject.keywordPlus | TESTS | - |
| dc.subject.keywordPlus | SENSITIZATION | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | TECHNOLOGY | - |
| dc.subject.keywordAuthor | Allergy | - |
| dc.subject.keywordAuthor | Allergic rhinitis | - |
| dc.subject.keywordAuthor | Allergen microarray | - |
| dc.subject.keywordAuthor | sIgE | - |
| dc.subject.keywordAuthor | In vitro diagnostics | - |
| dc.subject.keywordAuthor | Performance evaluation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
