Cited 2 time in
Hybrid-Mode Cuk Inverter with Low-Voltage Ride-Through Capability under Grid-Faults
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Han, B. | - |
| dc.contributor.author | Kim, M. | - |
| dc.contributor.author | Lai, J.-S. | - |
| dc.date.accessioned | 2023-04-28T05:42:05Z | - |
| dc.date.available | 2023-04-28T05:42:05Z | - |
| dc.date.issued | 2019-05 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/8569 | - |
| dc.description.abstract | This paper proposes a hybrid-mode Cuk inverter with low-voltage ride-through (LVRT) capability under grid-faults. It operates as an unfolding-type inverter during normal grid condition and two-stage inverter during abnormal grid condition. Thus, it normally transfers the energy to the utility grid highly efficiently, and also has the LVRT ability under grid-faults. Moreover, two types of inverters share the full-bridge circuit on the grid-side and so the proposed circuit can be developed with low cost and reduced size. This paper outlines operation principles and control methods for the proposed inverter. The prototype of the proposed converter was implemented and experimental tests were carried out to demonstrate its practical feasibility. © 2019 The Korean Institute of Power Electronics (KIPE). | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
| dc.title | Hybrid-Mode Cuk Inverter with Low-Voltage Ride-Through Capability under Grid-Faults | - |
| dc.type | Article | - |
| dc.identifier.scopusid | 2-s2.0-85071620749 | - |
| dc.identifier.bibliographicCitation | ICPE 2019 - ECCE Asia - 10th International Conference on Power Electronics - ECCE Asia, pp 2892 - 2898 | - |
| dc.citation.title | ICPE 2019 - ECCE Asia - 10th International Conference on Power Electronics - ECCE Asia | - |
| dc.citation.startPage | 2892 | - |
| dc.citation.endPage | 2898 | - |
| dc.type.docType | Conference Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordAuthor | Fault-ride through | - |
| dc.subject.keywordAuthor | Grid-connected inverter | - |
| dc.subject.keywordAuthor | Reactive power control | - |
| dc.subject.keywordAuthor | Repetitive control | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
