Cited 18 time in
Dielectrophoresis-based filtration effect and detection of amyloid beta in plasma for Alzheimer's disease diagnosis
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Hye Jin | - |
| dc.contributor.author | Park, Dongsung | - |
| dc.contributor.author | Baek, Seung Yeop | - |
| dc.contributor.author | Yang, Seung-Hoon | - |
| dc.contributor.author | Kim, YoungSoo | - |
| dc.contributor.author | Lim, Sang Moo | - |
| dc.contributor.author | Kim, Jinsik | - |
| dc.contributor.author | Hwang, Kyo Seon | - |
| dc.date.accessioned | 2023-04-28T04:42:11Z | - |
| dc.date.available | 2023-04-28T04:42:11Z | - |
| dc.date.issued | 2019-03-01 | - |
| dc.identifier.issn | 0956-5663 | - |
| dc.identifier.issn | 1873-4235 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/8307 | - |
| dc.description.abstract | The filtration effect improves the impedance change through specific binding of target molecules in plasma, and decreases this change by nonspecific binding of matrix factors in plasma (i.e., matrix effect). A difference in dielectrophoresis (DEP) forces applied to target molecules and matrix factors causes the filtration effect. An optimized DEP force affects target molecules, which remain in the reaction region of an interdigitated micro electrode (IME) sensor. Various matrix factors, which are larger than the target molecules, are influenced by a strong DEP force and are filtered out of the reaction region. To demonstrate the filtration effect, the matrix effect was confirmed in standard plasma and in phosphate-buffered saline, based on the detection of amyloid beta (A beta), an Alzheimer's disease (AD)-associated peptide. The filtration effect was verified using the matrix effect factor (MEF), which was calculated from the impedance change values in different detection environments. In standard plasma, the MEF value decreased by approximately 78.12%, and in buffer with heterogeneous A beta, by approximately 75.43%. Plasma from patients with AD and normal controls (NCs) was analyzed using the value of the impedance change by the filtration effect. The impedance change was enhanced approximately 1.52 +/- 0.03-fold in AD plasma, but declined approximately 0.90 +/- 0.03-fold in NC plasma. This difference tendency by the filtration effect was the disease evaluation index and used as an important criterion that distinguished between the AD and NC plasma. Plasma-based AD diagnosis may be possible, based on the filtration effect. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | ELSEVIER ADVANCED TECHNOLOGY | - |
| dc.title | Dielectrophoresis-based filtration effect and detection of amyloid beta in plasma for Alzheimer's disease diagnosis | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.bios.2018.12.046 | - |
| dc.identifier.scopusid | 2-s2.0-85060055262 | - |
| dc.identifier.wosid | 000457950200023 | - |
| dc.identifier.bibliographicCitation | BIOSENSORS & BIOELECTRONICS, v.128, pp 166 - 175 | - |
| dc.citation.title | BIOSENSORS & BIOELECTRONICS | - |
| dc.citation.volume | 128 | - |
| dc.citation.startPage | 166 | - |
| dc.citation.endPage | 175 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Biophysics | - |
| dc.relation.journalResearchArea | Biotechnology & Applied Microbiology | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
| dc.relation.journalWebOfScienceCategory | Biophysics | - |
| dc.relation.journalWebOfScienceCategory | Biotechnology & Applied Microbiology | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
| dc.subject.keywordPlus | BLOOD-SERUM | - |
| dc.subject.keywordPlus | PROTEIN | - |
| dc.subject.keywordPlus | BIOSENSOR | - |
| dc.subject.keywordPlus | CHROMATOGRAPHY | - |
| dc.subject.keywordPlus | SEPARATION | - |
| dc.subject.keywordPlus | BLOCKING | - |
| dc.subject.keywordPlus | URINE | - |
| dc.subject.keywordAuthor | Dielectrophoresis | - |
| dc.subject.keywordAuthor | Filtration effect | - |
| dc.subject.keywordAuthor | Alzheimer's disease | - |
| dc.subject.keywordAuthor | Plasma-based diagnosis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
