| dc.contributor.author | Kim, Eun-Kyung | - |
| dc.contributor.author | Kim, Jinuk | - |
| dc.contributor.author | Choi, Han Ho | - |
| dc.contributor.author | Jung, Jin-Woo | - |
| dc.date.accessioned | 2023-04-28T03:41:08Z | - |
| dc.date.available | 2023-04-28T03:41:08Z | - |
| dc.date.issued | 2019-06 | - |
| dc.identifier.issn | 1551-3203 | - |
| dc.identifier.issn | 1941-0050 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/8070 | - |
| dc.description.abstract | This paper proposes a variable structure speed controller (VSSC) that guarantees the robust transient performance against the external disturbances and parameter uncertainties of an interior permanent magnet synchronous motor (IPMSM) drive. Unlike the conventional VSSC applied to the IPMSMs, the proposed nonlinear compensating control term not only assures the robustness against the system uncertainties, but also implements the maximum torque per ampere technique. Furthermore, the convergence and stability of the proposed VSSC are fully proven through the Lyapunov theory by introducing reasonable bounded uncertainties which determine a feasible range for the system dynamics. The effectiveness of the proposed scheme is investigated through the simulation using MATLAB/Simulink and experiment using a prototype IPMSM drive system with a TI TMS320F28335 DSP. Finally, the proposed VSSC can ensure faster and more robust transient response than the conventional proportional-integral speed controller under the dynamic load conditions including the uncertainties. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
| dc.title | Variable Structure Speed Controller Guaranteeing Robust Transient Performance of an IPMSM Drive | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TII.2018.2873424 | - |
| dc.identifier.scopusid | 2-s2.0-85054346549 | - |
| dc.identifier.wosid | 000471725400017 | - |
| dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, v.15, no.6, pp 3300 - 3310 | - |
| dc.citation.title | IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS | - |
| dc.citation.volume | 15 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 3300 | - |
| dc.citation.endPage | 3310 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Automation & Control Systems | - |
| dc.relation.journalResearchArea | Computer Science | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Automation & Control Systems | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Industrial | - |
| dc.subject.keywordPlus | MAGNET SYNCHRONOUS MOTORS | - |
| dc.subject.keywordPlus | TRACKING CONTROL | - |
| dc.subject.keywordPlus | PI-CONTROLLER | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordPlus | MTPA | - |
| dc.subject.keywordAuthor | Disturbances | - |
| dc.subject.keywordAuthor | interior permanent magnet synchronous motor (IPMSM) | - |
| dc.subject.keywordAuthor | speed control | - |
| dc.subject.keywordAuthor | uncertainties | - |
| dc.subject.keywordAuthor | variable structure control (VSC) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.