Detailed Information

Cited 5 time in webofscience Cited 5 time in scopus
Metadata Downloads

Kinetic analysis of cardiac compressions during cardiopulmonary resuscitation

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Yong Won-
dc.contributor.authorCha, Kyoung-Chul-
dc.contributor.authorKim, Yun Seob-
dc.contributor.authorCha, Yong Sung-
dc.contributor.authorKim, Hyun-
dc.contributor.authorLee, Kang Hyun-
dc.contributor.authorHwang, Sung Oh-
dc.date.accessioned2023-04-28T03:40:42Z-
dc.date.available2023-04-28T03:40:42Z-
dc.date.issued2019-08-
dc.identifier.issn0883-9441-
dc.identifier.issn1557-8615-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/7866-
dc.description.abstractPurpose: Little is known about the dynamics of cardiac compression during cardiopulmonary resuscitation (CPR). The purpose of this study was to investigate the dynamics of chest compressions by analyzing movement of the right ventricular free wall excursion during CPR. Materials and methods: Patients older than 18 years with non-traumatic cardiac arrest who received CPR were enrolled. During CPR, transesophageal echocardiography (TEE) was performed and M-mode tracing was performed at the maximal compression area of the right ventricular free wall to measure the dynamics of cardiac compression. Results: Twenty patients (mean age, 71 years; 14 males) were enrolled. The median compression depth of the right ventricular free wall was 34.4 (IQR 24.5-44.5) mm. The median duration of one compression-relaxation cycle was 0.59 (IQR 0.58-0.60) s, which comprised 0.23 (IQR 0.19-0.27) s of compression and 0.36 (IQR 032-0.39) sof relaxation. The median compression velocity was 162 (IQR 95-215) mm/s. and the median relaxation velocity was 93 (IQR 75-121) mm/s. Compression depth was linearly correlated with mean compression velocity (r = 0.882, p < 0.001). Compression velocity had a negative correlation with the ratio of compression-relaxation time (r = -0.711, p < 0.001). Conclusions: Maintaining high compression velocity is helpful in achieving adequate compression depth during CPR. (C) 2019 Elsevier Inc. All rights reserved.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherW B SAUNDERS CO-ELSEVIER INC-
dc.titleKinetic analysis of cardiac compressions during cardiopulmonary resuscitation-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.jcrc.2019.04.003-
dc.identifier.scopusid2-s2.0-85063905530-
dc.identifier.wosid000471240500007-
dc.identifier.bibliographicCitationJOURNAL OF CRITICAL CARE, v.52, pp 48 - 52-
dc.citation.titleJOURNAL OF CRITICAL CARE-
dc.citation.volume52-
dc.citation.startPage48-
dc.citation.endPage52-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryCritical Care Medicine-
dc.subject.keywordPlusTRANSESOPHAGEAL ECHOCARDIOGRAPHY-
dc.subject.keywordPlusDEPTH-
dc.subject.keywordPlusQUALITY-
dc.subject.keywordPlusCPR-
dc.subject.keywordPlusACCELEROMETER-
dc.subject.keywordPlusOUTCOMES-
dc.subject.keywordPlusDEVICE-
dc.subject.keywordPlusRATES-
dc.subject.keywordAuthorCardiopulmonary resuscitation-
dc.subject.keywordAuthorCardiac arrest-
dc.subject.keywordAuthorTransesophageal-
dc.subject.keywordAuthorEchocardiography-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE