Effect of Gradient Linearity and Static Magnetic Field Homogeneity on Diffusion Weighted Image: A Phantom Study
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Ho-Beom | - |
| dc.contributor.author | Han, Yong-Soo | - |
| dc.contributor.author | Kim, Sung-Min | - |
| dc.date.accessioned | 2023-04-27T23:40:28Z | - |
| dc.date.available | 2023-04-27T23:40:28Z | - |
| dc.date.issued | 2020-06 | - |
| dc.identifier.issn | 1226-1750 | - |
| dc.identifier.issn | 2233-6656 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/6577 | - |
| dc.description.abstract | In this study, we assessed image quality and geometric accuracy as a function of the gradient physical linearity used for diffusion-weighted imaging (DWI) on both conventional-bore and wide-bore scanners. The signal to noise ratio (SNR) was calculated using b = 1000 DWI images for all acquisitions. To evaluate geometric accuracy, the diameter of a phantom on an image slice was measured in four directions. In comparison with the enhanced gradient mode, the default and maximum gradient modes showed higher SNRs with both bore sizes. There were significant differences in SNR among the various gradient modes of the two bore sizes. The geometric accuracy evaluations showed no statistically significant differences in the measured lengths among the various gradient modes and both bore sizes. The wide bore using default and maximum gradient mode showed higher SNR than the conventional bore, and comparable geometric accuracy. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN MAGNETICS SOC | - |
| dc.title | Effect of Gradient Linearity and Static Magnetic Field Homogeneity on Diffusion Weighted Image: A Phantom Study | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.4283/JMAG.2020.25.2.157 | - |
| dc.identifier.scopusid | 2-s2.0-85090733568 | - |
| dc.identifier.wosid | 000551277100007 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF MAGNETICS, v.25, no.2, pp 157 - 163 | - |
| dc.citation.title | JOURNAL OF MAGNETICS | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 157 | - |
| dc.citation.endPage | 163 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002601206 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
| dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
| dc.relation.journalWebOfScienceCategory | Physics, Condensed Matter | - |
| dc.subject.keywordPlus | PERIPHERAL-NERVE STIMULATION | - |
| dc.subject.keywordPlus | BIOPSY | - |
| dc.subject.keywordPlus | HEAD | - |
| dc.subject.keywordPlus | MRI | - |
| dc.subject.keywordAuthor | MR-Imaging | - |
| dc.subject.keywordAuthor | gradient physical linearity | - |
| dc.subject.keywordAuthor | static magnetic homogeneity | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.