Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

자기 제어 캡슐내시경을 이용한 상부위장관 검사

Full metadata record
DC Field Value Language
dc.contributor.author오동준-
dc.contributor.author임윤정-
dc.date.accessioned2026-02-26T17:30:20Z-
dc.date.available2026-02-26T17:30:20Z-
dc.date.issued2026-01-
dc.identifier.issn1598-9992-
dc.identifier.issn2233-6869-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/63804-
dc.description.abstractEsophagogastroduodenoscopy (EGD) is the standard diagnostic modality for upper gastrointestinal (UGI) diseases, but its invasive nature and the risk of sedation-related adverse events limit its applicability in certain patients. Magnetically controlled capsule endoscopy (MCE) is a promising noninvasive alternative, enabling precise active locomotion and complete visualization of the gastric mucosa through external magnetic control. MCE systems have evolved into hand-held and robotic systems, with clinical studies showing diagnostic performance comparable to EGD, along with generally better patient tolerance. Recent studies have shown that a single MCE examination can simultaneously evaluate the UGI tract and small bowel. Advances such as three-dimensional imaging and artificial intelligence have improved diagnostic accuracy and workflow efficiency. Although cost-effectiveness remains a challenge in Korea’s healthcare environment, MCE provides a meaningful alternative for patients who are unsuitable for sedated EGD or who prefer a noninvasive modality. With the ongoing technological advances, MCE is expected to evolve into an autonomous, “One-stop pan-enteric endoscopy” platform in the near future.-
dc.format.extent7-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한소화기학회-
dc.title자기 제어 캡슐내시경을 이용한 상부위장관 검사-
dc.title.alternativeMagnetically Controlled Capsule Endoscopy for Upper Gastrointestinal Examination-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.4166/kjg.2025.149-
dc.identifier.scopusid2-s2.0-105028341416-
dc.identifier.wosid001682924900003-
dc.identifier.bibliographicCitation대한소화기학회지, v.86, no.1, pp 16 - 22-
dc.citation.title대한소화기학회지-
dc.citation.volume86-
dc.citation.number1-
dc.citation.startPage16-
dc.citation.endPage22-
dc.type.docTypeReview-
dc.identifier.kciidART003298847-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClassesci-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaGastroenterology & Hepatology-
dc.relation.journalWebOfScienceCategoryGastroenterology & Hepatology-
dc.subject.keywordPlusCONVENTIONAL GASTROSCOPY-
dc.subject.keywordPlusFEASIBILITY-
dc.subject.keywordPlusSTOMACH-
dc.subject.keywordAuthorCapsule endoscopy-
dc.subject.keywordAuthorMagnetics-
dc.subject.keywordAuthorStomach-
dc.subject.keywordAuthorUpper gastrointestinal tract-
dc.subject.keywordAuthorRobotics-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Yun Jeong photo

Lim, Yun Jeong
Graduate School (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE