대동맥 인조혈관 원형 스테이플 문합에서의 누출 위험 분석 : 유한요소 시뮬레이션 기반 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 서명재 | - |
| dc.contributor.author | 권지연 | - |
| dc.contributor.author | 김성민 | - |
| dc.date.accessioned | 2025-09-25T08:00:14Z | - |
| dc.date.available | 2025-09-25T08:00:14Z | - |
| dc.date.issued | 2025-08 | - |
| dc.identifier.issn | 1229-0807 | - |
| dc.identifier.issn | 2288-9396 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/61622 | - |
| dc.description.abstract | Aortic aneurysms, caused by abnormal expansion of the aortic wall, pose critical risks upon rupture. Cir- cular stapler anastomosis offers a faster and safer alternative to suturing. This study evaluates leakage risk and fix- ation strength in aortic graft circular stapler anastomosis using finite element analysis (FEA). A simplified FEA model was developed and validated using existing leakage pressure data. Key parameters, including inter-row distance, tri- ple-row structure and triple-row spacing were analyzed. The Factor of Safety (FoS) was defined to quantitatively com- pare leakage risks under varying conditions. The inter-row distance critically influenced leakage risk, with wider gaps increasing leakage likelihood. Conversely, the triple-row structure significantly enhanced fixation strength, reducing leakage risk. Internal spacing within the triple-row exhibited minimal sensitivity. This study establishes a design framework for safer and more effective aortic graft circular stapler anastomosis. Findings provide foundational data for optimizing design and assessing leakage risk. | - |
| dc.format.extent | 10 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한의용생체공학회 | - |
| dc.title | 대동맥 인조혈관 원형 스테이플 문합에서의 누출 위험 분석 : 유한요소 시뮬레이션 기반 연구 | - |
| dc.title.alternative | Leakage Risk Analysis in Aortic Graft Circular Stapler Anastomosis: A Finite Element Simulation Study | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.9718/JBER.2025.46.4.366 | - |
| dc.identifier.bibliographicCitation | 의공학회지, v.46, no.4, pp 366 - 375 | - |
| dc.citation.title | 의공학회지 | - |
| dc.citation.volume | 46 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 366 | - |
| dc.citation.endPage | 375 | - |
| dc.type.docType | Y | - |
| dc.identifier.kciid | ART003239072 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Aortic aneurysm | - |
| dc.subject.keywordAuthor | Circular stapler | - |
| dc.subject.keywordAuthor | Leakage risk | - |
| dc.subject.keywordAuthor | Finite element analysis | - |
| dc.subject.keywordAuthor | Factor of safety | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.