Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Validity evidence of a task trainer for normal and difficult lumbar puncture A cross-sectional study

Full metadata record
DC Field Value Language
dc.contributor.authorAkaishi, Yu-
dc.contributor.authorOkada, Yuito-
dc.contributor.authorLee-Jayaram, Jannet-
dc.contributor.authorSeo, Jun Seok-
dc.contributor.authorYamada, Toru-
dc.contributor.authorBerg, Benjamin Worth-
dc.date.accessioned2023-04-27T21:40:33Z-
dc.date.available2023-04-27T21:40:33Z-
dc.date.issued2020-10-09-
dc.identifier.issn0025-7974-
dc.identifier.issn1536-5964-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/6015-
dc.description.abstractValidation of the anatomically complex configurations of the Lumbar Puncture Simulator II (KYOTO KAGAKU CO., LTD., 15 Kitanekoya-cho Fushimi-ku Kyoto, Japan 612-8388) have not been reported. Previous validation of the normal anatomic configuration has been reported. This study aims to evaluate evidence for construct and content validity of 4 interchangeable lumbar puncture (LP) complex anatomic configurations of this simulator. We performed a cross-sectional study between April 2018 and May 2019. Novice volunteer medical students and expert physicians who had performed over 30 LP procedures performed sequential LP procedures on each of 4 simulated interchangeable anatomic LP puncture blocks (normal, obesity, geriatric, combined geriatric/obesity). Primary outcome measures compared between groups for each LP procedure were return of cerebrospinal fluid within 5 minutes and a calculated performance score. Subjective face validity and content validity 5-point Likert questionnaires were completed by participants. 35 novice (n = 19) and expert (n = 16) subjects completed 140 procedures. Significant differences were found between novice and expert groups for both cerebrospinal fluid success rates and performance scores for normal (P = .001/P = .001) geriatric (P = .005/P = .002) and obesity (P = .003/P = < .001) configurations. There were no differences for the geriatric/obesity configuration. Expert median score of simulator realism (face validity) was 4 (range 3-4); median score of utility as a training tool (content validity) was 4 (range 4-5). We provide evidence for construct validity for each of the complex LP configurations, except combined geriatric/obesity. Expert physicians found the simulator sufficiently realistic to effectively teach LP skills.-
dc.language영어-
dc.language.isoENG-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.titleValidity evidence of a task trainer for normal and difficult lumbar puncture A cross-sectional study-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1097/MD.0000000000022622-
dc.identifier.scopusid2-s2.0-85092683920-
dc.identifier.wosid000579245800068-
dc.identifier.bibliographicCitationMEDICINE, v.99, no.41-
dc.citation.titleMEDICINE-
dc.citation.volume99-
dc.citation.number41-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusSIMULATION-BASED EDUCATION-
dc.subject.keywordPlusVENOUS CATHETER INSERTION-
dc.subject.keywordPlusCONSTRUCT-VALIDITY-
dc.subject.keywordPlusCARE-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusVALIDATION-
dc.subject.keywordPlusQUALITY-
dc.subject.keywordAuthorconstruct validity-
dc.subject.keywordAuthorlumbar puncture-
dc.subject.keywordAuthormedical education-
dc.subject.keywordAuthortask trainer-
dc.subject.keywordAuthorvalidation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE