Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A GQD/g-C3N4-modified nanochip for electrochemical detection of dengue serotype 3

Authors
Poria, RenuKaushal, AnkurVerma, ShrutiRamasamy, Selva KumarGhodake, GajananKumar, DeepakGupta, Shagun
Issue Date
May-2025
Publisher
Royal Society of Chemistry
Keywords
Graphite; Dna Probes; Dna, Viral; Graphite; Graphitic Carbon Nitride; Nitriles; Nitrogen Compounds; Biochips; Differential Pulse Voltammetry; Dna Probe; Dna Sensors; Electrochemical Detection; Ftir; Graphenes; Nanochips; Printed Papers; Screen-printed; Serotypes; Cyclic Voltammetry; Graphite; Graphitic Carbon Nitride; Nitrile; Nitrogen Derivative; Quantum Dot; Virus Dna; Blood Group Typing; Chemistry; Dengue; Dengue Virus; Devices; Diagnosis; Dna Probe; Electrochemical Analysis; Electrode; Genetic Procedures; Genetics; Human; Isolation And Purification; Limit Of Detection; Procedures; Virology; Biosensing Techniques; Dengue; Dengue Virus; Dna Probes; Dna, Viral; Electrochemical Techniques; Electrodes; Graphite; Humans; Limit Of Detection; Nitriles; Nitrogen Compounds; Quantum Dots; Serogroup
Citation
Analyst, v.150, no.11, pp 2430 - 2439
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
Analyst
Volume
150
Number
11
Start Page
2430
End Page
2439
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/58411
DOI
10.1039/d5an00035a
ISSN
0003-2654
1364-5528
Abstract
A graphene quantum dot/2D graphitic carbon nitride (GQD)/g-C3N4-based ultrasensitive DNA biosensor was constructed using 5 ' aminated DNA probes immobilized onto the surface of a screen-printed paper electrode (SPPE) for detecting DENV 3 (dengue serotype 3). FTIR, UV-Vis, TEM, and particle size measurements were used to characterize the synthesized nanocomposites. These results were then used to fabricate an affordable DNA sensor based on an SPPE that detects DENV 3. Initially, bioinformatics methods were used to develop DNA probes unique to DENV 3. The findings indicated that the most effective DNA probe for identifying DENV 3 was a 20-nucleotide sequence, which was immobilized onto a GQD/g-C3N4-modified SPPE. The electrochemical response was studied via differential pulse voltammetry (DPV) and cyclic voltammetry (CV). The electrode surface at each step of fabrication was characterized via FE-SEM, EIS and FTIR. The developed DNA sensor showed excellent analytical performance in terms of LOD and sensitivity. In CV, the LOD was 1 pg mu l-1, with a sensitivity of 7993 ng mu A-1 mm-2. However, in DPV, the LOD and sensitivity were 1 pg mu l-1 and 11 116 ng mu A-1 mm-2, respectively. This method should be preferable in the future for detecting DENV 3 in biological and clinical samples.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biological and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ghodake, Gajanan Sampatrao photo

Ghodake, Gajanan Sampatrao
College of Life Science and Biotechnology (Department of Convergent Environmental Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE