Detailed Information

Cited 2 time in webofscience Cited 1 time in scopus
Metadata Downloads

The contactless/contact type detection technologies of Chemical Warfare Agents

Authors
Lama, SanjeebPark, HyewonKim, JinukKim, JihyunSeo, Byung YeolRamesh, SivalingamKim, Joo-Hyung
Issue Date
2021
Publisher
SPIE-INT SOC OPTICAL ENGINEERING
Keywords
chemical warfare agents; dimethyl methyl phosphonate; quartz crystal microbalance; quantum cascade lasers; surface acoustic wave
Citation
SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2021, v.11591
Indexed
SCOPUS
Journal Title
SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2021
Volume
11591
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/5671
DOI
10.1117/12.2585326
ISSN
0277-786X
1996-756X
Abstract
Chemical Warfare Agents (CWAs), powerful chemical weapons in warfare and armed conflict, were prohibited by the Organization for the Prohibition of Chemical Weapons (OPCW), but the danger persists because of its misuse in terrorism and warfare. It is crucial to detect them rapidly because exposure to small quantity of CWAs can cause lethal damage or death in a short time. Generally, they have been detected by various conventional techniques such as photoionization, ion mobility spectroscopy, flame photometry, and IR spectroscopy. But most of these methods possess a crucial challenge in being a portable detector because they are heavy, bulky, and consumes large power. In this study, the surface acoustic wave (SAW) sensor, quartz crystal microbalance (QCM) sensor, and quantum cascade lasers (QCL) were used to detect simulant of CWA. The SAW sensor and QCM sensor, a chemical detector based on piezoelectric substrates, detect chemical compounds using mass loading effect. It is caused by the adsorption of chemical compounds on the sensing material coated on the surface of the delay line. Therefore, the synthesis method, coating process, type, and concentration of sensing material have a prime effect on the sensitivity of the sensor. QCL was used to make a contactless small chemical detector with a mid-infrared photodetector, drive circuit, and optical hardware. Most CWAs have very high absorption rates and different absorption spectra in the range of 8-12 mu m wavelengths. This detection method provides real-time detection of CWAs based on advantages of being contactless, excellent selectivity, and high sensitivity.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical, Robotics and Energy Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE