Cited 2 time in
Optimization of steam-methane reforming process using PSA off gas
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Oh, Taekgyeong | - |
| dc.contributor.author | Lee, Sangyong | - |
| dc.date.accessioned | 2024-12-09T07:30:15Z | - |
| dc.date.available | 2024-12-09T07:30:15Z | - |
| dc.date.issued | 2024-12 | - |
| dc.identifier.issn | 0360-3199 | - |
| dc.identifier.issn | 1879-3487 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/56320 | - |
| dc.description.abstract | This study aims to analyze the effect of PSA off gas utilization on fuel processing system combined with PSA (Pressure Swing Adsorption) system to produce more than 99% hydrogen for LT-PEMFC (Low Temperature Proton Exchange Membrane Fuel Cell) supply. An analysis was performed to optimize the operating conditions of a fuel processing system coupled with a PSA system by utilizing PSA off-gas to supply hydrogen to a 10 kW LT-PEMFC system. The performance and efficiency of the entire system were investigated at a steam-methane reactor temperature of 600 °C–800 °C, a water gas conversion reactor temperature of 200 °C–400 °C, a PSA recovery ratio of 60%–95%, a pressure of 1 bar, and 9 bar using Aspen Plus®, Aspen adsorption®, and Aspen Energy Analyzer® simulators. The sensitivities of various parameters affecting the process were analyzed to obtain optimized conditions for the entire system. Simulation results show that the optimal reformer temperature depends on the PSA recovery. The overall maximum efficiency is 78.67% at a process pressure of 9 bar the PSA recovery ratio of 95% and a temperature of 800 °C. In contrast, the highest efficiency under the 1 bar process condition is 70.55%, with an operating temperature of 600 °C and PSA recovery of 95%, which is relatively lower than the 9 bar process. Subsequently, pinch analysis and economic analysis including exergy analysis according to PSA recovery were conducted on these processes, showing that the thermal efficiency of the 9 bar process is relatively higher. The economic analysis indicated that the optimal profit is achieved at a PSA recovery of approximately 70∼75% and more than 40.2% of energy can be saved by utilizing PSA off gas to supply reaction heat for methane-steam reforming. © 2024 | - |
| dc.format.extent | 14 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier Ltd | - |
| dc.title | Optimization of steam-methane reforming process using PSA off gas | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.ijhydene.2024.11.149 | - |
| dc.identifier.scopusid | 2-s2.0-85209593535 | - |
| dc.identifier.wosid | 001397916800001 | - |
| dc.identifier.bibliographicCitation | International Journal of Hydrogen Energy, v.95, pp 902 - 915 | - |
| dc.citation.title | International Journal of Hydrogen Energy | - |
| dc.citation.volume | 95 | - |
| dc.citation.startPage | 902 | - |
| dc.citation.endPage | 915 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalResearchArea | Energy & Fuels | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Physical | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
| dc.subject.keywordPlus | HYDROGEN-PRODUCTION | - |
| dc.subject.keywordPlus | H-2 PSA | - |
| dc.subject.keywordPlus | FUEL | - |
| dc.subject.keywordPlus | GASIFICATION | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordPlus | POWER | - |
| dc.subject.keywordAuthor | Aspen simulation | - |
| dc.subject.keywordAuthor | Hydrogen production | - |
| dc.subject.keywordAuthor | Process optimization | - |
| dc.subject.keywordAuthor | PSA off gas | - |
| dc.subject.keywordAuthor | Reforming | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
