Cited 5 time in
Advanced dual mixed refrigerant (DMR) natural gas liquefaction plant with liquid air: Focus on configuration and optimization
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Mun, Haneul | - |
| dc.contributor.author | Kim, Dohee | - |
| dc.contributor.author | Park, Jinwoo | - |
| dc.contributor.author | Lee, Inkyu | - |
| dc.date.accessioned | 2024-12-03T00:30:20Z | - |
| dc.date.available | 2024-12-03T00:30:20Z | - |
| dc.date.issued | 2024-12 | - |
| dc.identifier.issn | 0360-5442 | - |
| dc.identifier.issn | 1873-6785 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/56285 | - |
| dc.description.abstract | This study introduces a novel approach to integrating LNG cold energy into the dual mixed refrigerant (DMR) process, employing liquid air as a cold energy carrier. The DMR process is chosen for natural gas liquefaction due to its flexibility in adjusting mixed refrigerant compositions when external cold sources are utilized. Two configurations are investigated: the low-pressure liquid air (LPLA) process, which relies solely on heat exchange, and the high-pressure liquid air (HPLA) process, which involves the pressurization and expansion of liquid air. Additionally, two optimization strategies are explored: 'With Composition' (WC) optimization, which includes refrigerant composition as a variable, and 'Without Composition' (WOC) optimization, which does not. Utilizing liquid air reduces the load on the refrigeration cycle, leading to improved performance compared to the conventional DMR process. The air expansion generates additional power and cold energy, while WC optimization further reduces the flow rate of low-boiling point components, significantly lowering compression energy consumption. As a result, the DMR-HPLA-WC process achieves a 44.17 % reduction in energy consumption, an 8.7 % improvement in exergy efficiency, and a 37.63 % decrease in specific costs. | - |
| dc.format.extent | 15 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier Ltd | - |
| dc.title | Advanced dual mixed refrigerant (DMR) natural gas liquefaction plant with liquid air: Focus on configuration and optimization | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.energy.2024.133747 | - |
| dc.identifier.scopusid | 2-s2.0-85208681042 | - |
| dc.identifier.wosid | 001357518000001 | - |
| dc.identifier.bibliographicCitation | Energy, v.313, pp 1 - 15 | - |
| dc.citation.title | Energy | - |
| dc.citation.volume | 313 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 15 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Thermodynamics | - |
| dc.relation.journalResearchArea | Energy & Fuels | - |
| dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
| dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
| dc.subject.keywordPlus | ENERGY-STORAGE | - |
| dc.subject.keywordPlus | SELECTION | - |
| dc.subject.keywordPlus | SINGLE | - |
| dc.subject.keywordAuthor | LNG supply chain | - |
| dc.subject.keywordAuthor | Cold energy recovery | - |
| dc.subject.keywordAuthor | Natural gas liquefaction | - |
| dc.subject.keywordAuthor | Liquid air | - |
| dc.subject.keywordAuthor | Dual mixed refrigerant process | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.