Cited 2 time in
Mechanism behind the paper spray chemical ionization phenomenon and the choice of solvent
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Hyungjun | - |
| dc.contributor.author | Lee, Hyunwoo | - |
| dc.contributor.author | Kum, Daesub | - |
| dc.contributor.author | Tae, Heungsik | - |
| dc.contributor.author | Cha, Sangwon | - |
| dc.contributor.author | Kim, Donghwi | - |
| dc.contributor.author | Kim, Sunghwan | - |
| dc.date.accessioned | 2023-04-27T18:40:28Z | - |
| dc.date.available | 2023-04-27T18:40:28Z | - |
| dc.date.issued | 2021-04 | - |
| dc.identifier.issn | 1076-5174 | - |
| dc.identifier.issn | 1096-9888 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/5167 | - |
| dc.description.abstract | Paper spray chemical ionization (PSCI) combined with mass spectrometry has been proposed as a sensitive method for the analysis of nonpolar aromatic compounds; however, the mechanism behind PSCI is not well understood. In the present study, the evidence for the occurrence of corona discharge is provided and its mechanism is proposed. Photographs taken with a highly sensitive camera evidently demonstrate the occurrence of corona discharge at the end of the triangular shape tip when a nonpolar solvent such as hexane was used at an applied potential of 6-7 kV. Nevertheless, corona discharge was not observed in the presence of a polar solvent. The occurrence of the corona discharge was attributed to charge accumulation in the dielectric layer generated by the nonpolar solvent on the fibers of the paper tip. Specifically, corona discharge was generated at the tip end when the charge approached a critical threshold. In the presence of a polar solvent, however, the dielectric layer was not generated and, hence, corona discharge was not observed. Based on this information, three nonpolar solvents were selected and their sensitivity for analyzing the phenanthrene and maltene fractions of crude oil was evaluated. Chlorobenzene provided the highest signal abundance; therefore, it was suggested as the optimum solvent for PSCI. Notably, the fundamental understanding of corona discharge in PSCI acquired in this study provides a basis for further improvement of this technique by way of surface modification. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | WILEY | - |
| dc.title | Mechanism behind the paper spray chemical ionization phenomenon and the choice of solvent | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1002/jms.4602 | - |
| dc.identifier.scopusid | 2-s2.0-85088386766 | - |
| dc.identifier.wosid | 000551937100001 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF MASS SPECTROMETRY, v.56, no.4 | - |
| dc.citation.title | JOURNAL OF MASS SPECTROMETRY | - |
| dc.citation.volume | 56 | - |
| dc.citation.number | 4 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Spectroscopy | - |
| dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Spectroscopy | - |
| dc.subject.keywordPlus | MASS-SPECTROMETRY | - |
| dc.subject.keywordPlus | REAL-TIME | - |
| dc.subject.keywordPlus | MOLECULAR-IONS | - |
| dc.subject.keywordPlus | DESORPTION | - |
| dc.subject.keywordPlus | PLASMA | - |
| dc.subject.keywordPlus | OPTIMIZATION | - |
| dc.subject.keywordPlus | GENERATION | - |
| dc.subject.keywordPlus | SAMPLES | - |
| dc.subject.keywordPlus | TISSUE | - |
| dc.subject.keywordPlus | DRUGS | - |
| dc.subject.keywordAuthor | corona discharge | - |
| dc.subject.keywordAuthor | dielectric constant | - |
| dc.subject.keywordAuthor | dielectric layer | - |
| dc.subject.keywordAuthor | mass spectrometry | - |
| dc.subject.keywordAuthor | paper spray chemical ionization | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
