Detailed Information

Cited 6 time in webofscience Cited 6 time in scopus
Metadata Downloads

Potentiometric Performance of a Highly Flexible-Shaped Trifunctional Sensor Based on ZnO/V2O5 Microrods

Full metadata record
DC Field Value Language
dc.contributor.authorAppiagyei, Alfred Bekoe-
dc.contributor.authorHan, Jeong In-
dc.date.accessioned2023-04-27T18:40:27Z-
dc.date.available2023-04-27T18:40:27Z-
dc.date.issued2021-04-
dc.identifier.issn1424-8220-
dc.identifier.issn1424-3210-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/5164-
dc.description.abstractA trifunctional flexible sensor was fabricated on a polyethylene terephthalate (PET) fiber surface. Synthesized ZnO and ZnO/V2O5 composite were coated on ZnO seed layer sputtered PET fiber. X-ray diffraction (XRD) and photoelectron spectroscopy (XPS) techniques confirmed the exact formation of ZnO and ZnO/V2O5. The fabricated ZnO/V2O5 on ZnO seeds base temperature sensor recorded better electrical properties and reversibility with a maximum temperature coefficient resistance (TCR) of 0.0111 degrees C-1. A calibration curve (R = 0.9941) within glucose concentration of (10 mu M-10 mM) was obtained at +0.8 V vs. Ag/AgCl from current-voltage curves which assisted in calculating glucose sensitivity, limit of detection (LOD), limit of quantification (LOQ). The electrode achieved an outstanding performance of sensitivity (72.06 mu AmM(-1)cm(-2)), LOD (174 mu M), and LOQ (582 mu M) at optimum deposition time. Interference from oxidation of interfering biomolecules such as ascorbic acid, dopamine, and uric acid were negligible compared to glucose. Finally, the fabricated electrode was employed as a pH sensor and displayed a pH sensitivity of 42.26 mV/pH (R = 0.9922). This fabricated ZnO/V2O5 electrode exhibited high sensitivity and a stable combined temperature, glucose, and pH sensor which is promising for development of multifunctional sensors in next generation wearables.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titlePotentiometric Performance of a Highly Flexible-Shaped Trifunctional Sensor Based on ZnO/V2O5 Microrods-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/s21072559-
dc.identifier.scopusid2-s2.0-85103543353-
dc.identifier.wosid000638869900001-
dc.identifier.bibliographicCitationSENSORS, v.21, no.7-
dc.citation.titleSENSORS-
dc.citation.volume21-
dc.citation.number7-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordAuthorflexible sensor-
dc.subject.keywordAuthorPET fiber-
dc.subject.keywordAuthorsimultaneous hydrothermal-
dc.subject.keywordAuthormultifunctional detectors-
dc.subject.keywordAuthorbending-
dc.subject.keywordAuthorwearables-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biochemical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE