Detailed Information

Cited 1 time in webofscience Cited 0 time in scopus
Metadata Downloads

End-Tidal Carbon Dioxide Monitoring for Spontaneous Pneumothorax

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Gyeong Min-
dc.contributor.authorKim, Yong Won-
dc.contributor.authorLee, Sanghun-
dc.contributor.authorDo, Han Ho-
dc.contributor.authorSeo, Jun Seok-
dc.contributor.authorLee, Jeong Hun-
dc.date.accessioned2023-04-27T17:40:20Z-
dc.date.available2023-04-27T17:40:20Z-
dc.date.issued2021-06-14-
dc.identifier.issn2090-2840-
dc.identifier.issn2090-2859-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/4802-
dc.description.abstractBackground. Spontaneous pneumothorax should be classified as primary spontaneous pneumothorax (PSP) or secondary spontaneous pneumothorax (SSP) because treatment strategies may differ depending on underlying lung conditions and clinical course. The pulmonary dysfunction can lead to changes in end-tidal carbon dioxide (ETCO2). The aim of this study was to investigate the difference in ETCO2 between PSP and SSP. Methods. This retrospective observational study included adult patients diagnosed with spontaneous pneumothorax in the emergency room from April 2019 to September 2020. We divided patients into PSP and SSP groups and compared ETCO2 variables between the two groups. Results. There were 33 (66%) patients in the PSP group and 17 (34%) patients in the SSP group. Initial ETCO2 was lower in the SSP group than in the PSP group (30 (23-33) vs. 35 (33-38) mmHg, p=0.002). Multivariate analysis revealed that respiratory gas associated with SSP was initial ETCO2 (OR: 0.824; 95% CI: 0.697-0.974, p=0.023). The optimal cutoff for initial ETCO2 to detection of SSP was 32 mmHg (area under curve, 0.754), with 76.5% sensitivity and 72.7% specificity. Conclusion. ETCO2 monitoring is a reliable noninvasive indicator of differentiating between PSP and SSP. Initial ETCO2 lower than 32 mmHg is a predictor of SSP.-
dc.language영어-
dc.language.isoENG-
dc.publisherHINDAWI LTD-
dc.titleEnd-Tidal Carbon Dioxide Monitoring for Spontaneous Pneumothorax-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1155/2021/9976543-
dc.identifier.wosid000669913500001-
dc.identifier.bibliographicCitationEMERGENCY MEDICINE INTERNATIONAL, v.2021-
dc.citation.titleEMERGENCY MEDICINE INTERNATIONAL-
dc.citation.volume2021-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.relation.journalResearchAreaEmergency Medicine-
dc.relation.journalWebOfScienceCategoryEmergency Medicine-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusSIZE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jeong Hun photo

Lee, Jeong Hun
Graduate School (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE