Detailed Information

Cited 5 time in webofscience Cited 6 time in scopus
Metadata Downloads

Improvement in Strain Sensor Stability by Adapting the Metal Contact Layer

Full metadata record
DC Field Value Language
dc.contributor.authorChoy, Ji-Yeon-
dc.contributor.authorJo, Eun-Bee-
dc.contributor.authorYim, Chang-Joo-
dc.contributor.authorYoui, Hae-Kyung-
dc.contributor.authorHwang, Jung-Hoon-
dc.contributor.authorLee, Jun-Ho-
dc.contributor.authorKim, Hyun-Seok-
dc.date.accessioned2023-04-27T13:41:04Z-
dc.date.available2023-04-27T13:41:04Z-
dc.date.issued2022-01-
dc.identifier.issn1424-8220-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/3790-
dc.description.abstractResearch on stretchable strain sensors is actively conducted due to increasing interest in wearable devices. However, typical studies have focused on improving the elasticity of the electrode. Therefore, methods of directly connecting wire or attaching conductive tape to materials to detect deformation have been used to evaluate the performance of strain sensors. Polyaniline (PANI), a p-type semiconductive polymer, has been widely used for stretchable electrodes. However, conventional procedures have limitations in determining an appropriate metal for ohmic contact with PANI. Materials that are generally used for connection with PANI form an undesirable metal-semiconductor junction and have significant contact resistance. Hence, they degrade sensor performance. This study secured ohmic contact by adapting Au thin film as the metal contact layer (the MCL), with lower contact resistance and a larger work function than PANI. Additionally, we presented a buffer layer using hard polydimethylsiloxane (PDMS) and structured it into a dumbbell shape to protect the metal from deformation. As a result, we enhanced steadiness and repeatability up to 50% strain by comparing the gauge factors and the relative resistance changes. Consequently, adapting structural methods (the MCL and the dumbbell shape) to a device can result in strain sensors with promising stability, as well as high stretchability.-
dc.format.extent17-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleImprovement in Strain Sensor Stability by Adapting the Metal Contact Layer-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/s22020630-
dc.identifier.scopusid2-s2.0-85122877727-
dc.identifier.wosid000758551000001-
dc.identifier.bibliographicCitationSensors, v.22, no.2, pp 1 - 17-
dc.citation.titleSensors-
dc.citation.volume22-
dc.citation.number2-
dc.citation.startPage1-
dc.citation.endPage17-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusPOLYANILINE-
dc.subject.keywordPlusNANOWIRE-
dc.subject.keywordAuthorstretchable sensor-
dc.subject.keywordAuthorstrain sensor-
dc.subject.keywordAuthorwearable device-
dc.subject.keywordAuthorpolyaniline-
dc.subject.keywordAuthorPDMS-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Electronics and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyun Seok photo

Kim, Hyun Seok
College of Engineering (Department of Electronics and Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE